Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2019-03-01T12:48:35Z
No. of bitstreams: 1
Rafael Ferreira Heissler_.pdf: 5310998 bytes, checksum: 8847fea2dddf83be1123bea3df10448c (MD5) / Made available in DSpace on 2019-03-01T12:48:36Z (GMT). No. of bitstreams: 1
Rafael Ferreira Heissler_.pdf: 5310998 bytes, checksum: 8847fea2dddf83be1123bea3df10448c (MD5)
Previous issue date: 2018-10-09 / Nenhuma / Atualmente no Brasil as construtoras necessitam projetar e construir edificações residenciais com condições mínimas de isolamento acústico, e para tal, as características acústicas do sistema construtivo devem ser bem conhecidas. Para as condições de projeto, utilizam-se dados de isolamento acústico dos sistemas ensaiados em laboratório como valores de input em simulações computacionais, e assim, estimar os resultados que poderão ser obtidos em ensaios em campo. Entretanto, os requisitos que o sistema deve atender, na atual norma brasileira, são fundamentados somente em ensaios experimentais em laboratório ou em campo, particularmente, não contemplando o uso de métodos de predição acústica para se estimar o desempenho em etapas de projeto. Isso acarreta em uma necessidade de amostragem total da edificação, uma vez que requisitos são estipulados de acordo com a situação de uso das unidades. Deste modo, este trabalho busca apresentar resultados da diferença padronizada de nível ponderado e nível de pressão sonora de impacto-padrão ponderado de diferentes sistemas construtivos ensaiados em uma mesma edificação, com foco na análise comparativa das diferentes áreas e geometrias e na estimativa obtida de softwares de predição acústica. Os ensaios foram realizados em edifícios residenciais situados na região de Porto Alegre, de acordo com as normas técnicas ISO 16283-1 e ISO 16283-2, e estimados com o uso de software SONarchitect. Uma análise da incerteza de medição a partir de uma série histórica de dados foi realizada para se verificar se há influência da geometria na incerteza expandida. Para a condição de ruído aéreo, verificou-se que parte dos ensaios apresentaram resultados simulados com valor menor que os encontrados através de ensaio, e a incerteza de medição tende a um valor maior conforme o aumento do volume do cômodo ensaiado. Já para os ensaios de transmissão ao ruído de impacto, os valores estimados ficaram muito próximos dos resultados de ensaio, entretanto, não foi possível relacionar a incerteza de medição com o volume do cômodo ensaiado. / Currently in Brazil, building companies need to design and construct residential buildings with a minimum of acoustic insulation conditions, and to this end, the acoustic characteristics of the constructive system must be well known. For the design situation, sound insulation data of the systems tested in the laboratory are used as input values in computational simulations, and thus, to estimate the results that can be obtained in field tests. However, the requirements only contemplate the minimum results that the system must have when performed in the laboratory and verified in the field situation, not allowing the use of acoustic prediction methods to estimate the performance in design stages. This entails a need for total sampling of the building since requirements are established according to the kind of the units. Thus, this study aims to present results of the weighted standardized sound level difference and weighted standardized impact sound pressure level of different building systems tested in the same building, with a focus on comparative analysis of different areas and geometry and obtained from estimation of acoustic prediction software. The tests were carried out in residential buildings located in the region of Porto Alegre, according to the technical standards ISO 16283-1 and ISO 16283-2, and estimated with the use of software SONarchitect. An analysis of the uncertainty of measurement from a historical data series was carried out to verify if there is influence of the geometry in the expanded uncertainty. For the airborne condition, it was found that part of the tests presented shown results with a lower value than those found by means of the test, and the measurement uncertainty tends to be higher as the volume of the room tested increases. However, for the impact noise transmission tests, the estimated values were very close to the test results, however, it was not possible to relate the measurement uncertainty to the volume of the room tested.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/7620 |
Date | 09 October 2018 |
Creators | Heissler, Rafael Ferreira |
Contributors | http://lattes.cnpq.br/1555729873996754, Oliveira, Maria Fernanda de |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Arquitetura e Urbanismo, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0047 seconds