Return to search

Nejistoty měření průtoku páry / Steam Flow Measurement Error Analysis

The thesis deals with analysis of measurement uncertainty. The theoretical knowledge presented in opening chapters is applied on indirect steam flow measurement by orifice plate. Calculation of steam flow is based on knowledge of pressure difference value, static pressure value and temperature. The data are acquired by experimental measurement in laboratory. The mass flow rate uncertainty is determined by normalized procedure (according to standard ČSN EN ISO 5167) and by detailed error analysis (according to standard ČSN ISO 5168) for comparison. Whole numerical computation employs python programming language in Spyder environment. Other computation result is steam consumption of washing cycle.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:318773
Date January 2017
CreatorsBarabášová, Iveta
ContributorsTouš, Michal, Bobák, Petr
PublisherVysoké učení technické v Brně. Fakulta strojního inženýrství
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess