Return to search

Avaliação do desempenho de um medidor de vazão eletromagnetico em situações praticas reais de instalação / Evaluation of the performance of an electromagnetic flowmeter in real practical situations of installation

Orientador: Ana Ines Borri Genovez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-06T04:58:32Z (GMT). No. of bitstreams: 1
Martim_AndreLuisSoteroSalustiano_M.pdf: 5209979 bytes, checksum: cd531521e2ae52a28d5dcfc9952e9dd2 (MD5)
Previous issue date: 2005 / Resumo: Martim, André Luís Sotero Salustiano. Avaliação do Desempenho de um Medidor de Vazão Eletromagnético em Situações Práticas Reais de Instalação. Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Universidade Estadual de Campinas, 2005. 182 páginas. Dissertação. A busca do melhor aproveitamento dos recursos hídricos é uma característica permanente nas políticas atuais, e o gerenciamento de recursos hídricos implica no equacionamento entre a vazão disponível e a vazão de demanda, ou seja, na medição de vazão. A partir de 2004 os usuários de recursos hídricos são obrigados a declarar os volumes de água captados, é a declaração anual de uso de recursos hídricos. A qualidade da vazão medida depende das técnicas de medição, e um dos principais fatores intervenientes é a condição de instalação do medidor. A avaliação de um medidor eletromagnético de vazão em condições práticas de instalação foi desenvolvida experimentalmente neste trabalho. O medidor de vazão eletromagnético utilizado foi instalado em quatro situações diferentes e os valores de vazão obtidos foram comparados com os de dois medidores instalados adequadamente, um medidor Venturi e um medidor Ultra-sônico. Os ensaios foram desenvolvidos em uma bancada no Laboratório de Hidráulica e Mecânica dos Fluidos da Faculdade de Engenharia Civil da Unicamp. Para a configuração com o medidor eletromagnético instalado à jusante de uma curva 900 de raio curto, o desvio máximo foi de 0,742% com uma incerteza de 0,27%. Para a configuração com o medidor eletromagnético instalado à jusante de duas curvas 900 de raio curto, o desvio máximo foi de 0,447% com uma incerteza de 0,74%. Para a configuração com o medidor eletromagnético instalado à jusante de uma válvula de gaveta, com 50% de abertura, o desvio máximo foi de -2,046% e uma incerteza de 0,50%. Os resultados obtidos mostram claramente que a condição de instalação do medidor frente às singularidades da tubulação afetam sua performance. Os valores de desvio de indicação podem ser considerados baixos ou altos, dependendo da exatidão exigida do medidor dentro do sistema / Abstract: Martim, André Luís Sotero Salustiano. Evaluation of the performance of an electromagnetic flowmeter in real practical situations of installation. Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Universidade Estadual de Campinas, 2005. The search of the best utilization of the water resources is a permanent characteristic in the current politics, and the management of water resources implies in the balance equally between the available flow and the flow of demand, or either, in the flow measurement. From 2004 the users of water resources are obliged to declare the caught volumes of water, is the annual declaration of use of water resources. The quality of the measured flow depends on the measurement techniques, and one of the main intervening factors is the condition of installation of the flowmeter. The evaluation of an electromagnetic flowmeter in practical conditions of installation was developed experimentally in this work. The electromagnetic flowmeter was installed in four different situations and the gotten values of flow measurement had been compared with the ones of two flowmeters installed adequately, an Venturi fi owmete r and an Ultrasonic flowmeter. The evaluation had been developed in a work-bench in the Laboratory of Hidraulical and Mechanic of fluid of the College of Civil Engineering of the Unicamp. For the configuration with the electromagnetic flowmeter installed downstream of a 90° elbow of short ray, the maximum deviation was of 0,742% with a 0,27% uncertainty. For the configuration with the electromagnetic flowmeter installed downstream of a two 90° elbow of short ray, the maximum deviation was of 0,447% with a 0,74% uncertainty. For the configuration with the installed electromagnetic flowmeter downstream a drawer valve, with 50% of opening, the maximum deviation was of a -2,046% and uncertainty of 0,50%. The gotten results show clearly that the condition of installation of the flowmeter front to the singularity of the tubing affects its performance. The values of deviation indication can be considered low or high, depending on the demanded accuracy of the flowmeter inside of the system / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257855
Date24 February 2005
CreatorsMartim, André Luís Sotero Salustiano, 1976-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Genovez, Ana Inés Borri, 1953-, Lucca, Yvone de Faria Lemos de, Coiado, Evaldo Miranda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format185p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds