Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-05T18:07:49Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoAlgoritmosEvolucionarios.pdf: 15152588 bytes, checksum: 17f1be44824b1303f352e08ae2bc2063 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2018-02-07T16:17:24Z (GMT) / Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-09T18:32:35Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoAlgoritmosMultiobjetivo.pdf: 7336466 bytes, checksum: 844408a690f2522ac2b67b232626c56f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-02-21T17:14:20Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoAlgoritmosMultiobjetivo.pdf: 7336466 bytes, checksum: 844408a690f2522ac2b67b232626c56f (MD5) / Made available in DSpace on 2018-02-21T17:14:20Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoAlgoritmosMultiobjetivo.pdf: 7336466 bytes, checksum: 844408a690f2522ac2b67b232626c56f (MD5)
Previous issue date: 2017-08-10 / O crescimento dos grandes centros urbanos traz como consequência imediata o aumento das cargas nos sistemas de distribuição. Além disso, a crescente demanda implica em igual crescimento no consumo de reativos, que, como já se sabe, são sinônimos de perdas nos sistemas de potência, bem como de comprometimento de alguns de seus componentes. Dessa forma, é grande o desafio das concessionárias de distribuição de energia elétrica, uma vez que a dinâmica da carga imprime um maior esforço no que diz respeito ao planejamento da expansão e de melhorias no sistema. Como forma de mitigar os problemas gerados, a instalação de bancos de capacitores surge como solução prática, econômica e consolidada tecnicamente. Entretanto, há de se pensar no dimensionamento e posição de instalação dos bancos, de modo que alcancem o melhor desempenho possível. Paralelamente, o crescimento de cargas nos sistemas de distribuição introduz um novo paradigma, a presença de harmônicos provenientes de cargas não lineares. Uma das peculiaridades da presença simultânea de harmônicos e capacitores dentro de uma mesma rede elétrica é a possibilidade de ocorrência do fenômeno da ressonância, em que o valor das amplitudes de alguns componentes harmônicos ultrapassam os limites aceitáveis, produzindo diversos efeitos indesejados. Nesse contexto, este trabalho propõe a comparação entre duas técnicas evolucionárias de otimização multiobjetivo, o NSGA-II e o SPEA2, para a solução do Problema de Alocação e Dimensionamento de Bancos de Capacitores (PADBC) em redes de distribuição radiais, considerando os efeitos dos harmônicos na presença de cargas não lineares. / The rapid growth of urban areas bring, as a consequence, an increase in the amount of loads connected to the distribution grids. Furthermore, the increase in the demand implies in equal raise in reactive loads, which are known to cause losses in the network. Thus, the utilities have a great challenge ahead, as the dynamics of the load require a greater effort in terms of expansion and improvements of the grid. In an attempt to mitigate the problems caused, the allocation of capacitor banks can become a practical, economical and technically robust solution. Nevertheless, it is extremely important to analyze the sizing and positioning of the banks, in order to achieve the best possible outcome. In parallel, the increasing use of nonlinear loads cause harmonics to appear in the system. When in conjunction with capacitor banks, it is possible to develop the far more dangerous phenomenon of resonance, where the amplitude of some of the harmonics goes beyond acceptable limits, resulting in undesirable effects. In this context, this work proposes a comparison between two multiobjective optimization tehcniques, NSGA-II and SPEA2, to solve the problem of sizing and placement of capacitor banks in electric energy distribution grids, considering the effects of harmonics produced by nonlinear loads.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9476 |
Date | 10 August 2017 |
Creators | KATAOKA, Vitor da Silva |
Contributors | TOSTES, Maria Emília de Lima, BEZERRA, Ubiratan Holanda |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | 1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds