The aim of this thesis is to investigate PMSM models with internal faults. Two fault models are introduced. One of them is suitable for simulation of stator winding inter-turn short fault in case of one pole-pair motor and other one for simulation of inter-turn fault in case of multiple pole-pair motor. There are described some methods for model based fault detection of internal faults and sensor faults.