The gravitational wave observatory and many other large ground-based instruments need to be decoupled from the Earth’s ever-present motion to improve their performance. In such scenarios, inertial sensors which measure the ground motion are necessary, especially those with a high resolution and a large dynamic range. This thesis aims to develop high performance inertial sensors which outperform the commercially available ones in terms of resolution and dynamic range in low frequency down to 0.01 Hz.Inertial sensors essentially consist of two parts: a single-degree-of-freedom mechanism and a transducer which converts mechanical quantities into electrical quantities. In this work, a novel interferometric readout based on homodyne quadrature interferometer is proposed and examined. Experimental results show that its resolution is 1e-11, 1e-12 and 2e-13 m/rtHz at 0.01, 0.1 and 1 Hz respectively. For the mechanical parts, the leaf spring pendulum and Lehman pendulum are used respectively as the restoring springs for the vertical and horizontal inertial sensors. With these, the resonance frequencies are made to 0.26 and 0.11 Hz, respectively. Combined with the interferometric readout, a Vertical Interferometric Inertial Sensor (VINS) and a Horizontal Interferometric Inertial Sensor (HINS) are developed. They are placed together in a vacuum chamber as an inertial unit to measure vertical and horizontal motion.A critical investigation of the developed HINS and VINS is performed. The passive VINS and HINS are compared, firstly, with a commercial seismometer (Guralp 6T) the results showed that they provide equivalent seismograms in frequencies from tides to 10 Hz. Secondly, both simulations and measurements have been conducted in this study, a noise budget of the interferometric readout itself was constructed, which corresponds to the case when the proof-mass of the inertial sensors is blocked. At present, the resolution of the interferometric readout is found to be limited by the photodetector noise from 0.01 to 1 Hz. Moreover, huddle tests were conducted for the inertial units to examine their overall performance. However, extra experiments and simulations are performed and it is found that the resolution identified from the experimental means is worse than that from the simulation. Nevertheless, the mismatch can be reduced by reducing the magnitude of input ground vibration, by reducing undesired inputs and improving the stability of the interferometric readout output signal. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished
Identifer | oai:union.ndltd.org:ulb.ac.be/oai:dipot.ulb.ac.be:2013/317532 |
Date | 13 January 2021 |
Creators | Ding, Binlei |
Contributors | Collette, Christophe, Lambert, Pierre, Deraemaeker, Arnaud, Van Camp, Michel, Bertolini, Alessandro |
Publisher | Universite Libre de Bruxelles, Université libre de Bruxelles, Ecole polytechnique de Bruxelles – Electromécanicien, Bruxelles |
Source Sets | Université libre de Bruxelles |
Language | English |
Detected Language | English |
Type | info:eu-repo/semantics/doctoralThesis, info:ulb-repo/semantics/doctoralThesis, info:ulb-repo/semantics/openurl/vlink-dissertation |
Format | 3 full-text file(s): application/pdf | application/pdf | application/pdf |
Rights | 3 full-text file(s): info:eu-repo/semantics/closedAccess | info:eu-repo/semantics/openAccess | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0016 seconds