This thesis deals with time-frequency analysis of electrograms measured on isolated guinea pig hearts perfused according to Langendorff. Time-frequency analysis is based on algorithms Matching Pursuit and Wigner-Ville Distribution. The theoretical part describes the basics of electrocardiography, measurement on isolated hearts, the theory of approximation method Matching Pursuit and its combination with the Wigner-Ville distribution spectrum showing the energy density of the signal. Also other common approaches of time-frequency analysis are presented including the theory of continuous wavelet transform. The presented algorithms were tested on a set of electrograms, on which were induced ischemia within measurement followed by reperfusion. The proposed method allows for the fast detection of ischemia without any a priori knowledge of the signal, and also serves as a tool for measurement of EG important points and intervals. In the conclusion efficacy of the method was presented and its possible uses has been discussed.