Jämförelse av kemiinstrument och validering av referensintervall hos hund och katt / Comparison of chemical instruments and validation of reference intervals in dogs and cats

Klinisk kemiska analyser har hög klinisk relevans. I serum/plasma kan olika parametrar kvantifieras. Dessa parametrar kan vara proteiner, enzymer, joner, metaller, lipider och kolhydrater. Med hjälp av referensintervall kan veterinärer ställa diagnos, följa behandling och sjukdomsförlopp. Parametrar detekteras med olika analysprinciper/metoder; kolorimetri, immunturbidimetri, enzymatisk metod och potentiometri. Djursjukhuset, AniCura, i Hässleholm mottagas både hundar och katter. Cirka 120 kemianalyser analyseras varje dag. AniCura har köpt in ett nytt våtkemiiinstrument, Indiko Plus, som ska ersätta Cobas C111. Med Indiko Plus tillkommer fler provpositioner, 8 nya analyser, ökad kapaciteten och underlättad användning.  Syftet med denna studie var att jämföra instrumenten och ta fram eget referensintervall som jämfördes med referensintervall framtaget av Thermo Fisher. Verifiering av det nya instrumentet genomfördes med precisionsstudie och linjäritetsstudie. Provtagning på hundar och katter utfördes av personal på AniCura. Jämförelsen gjordes med patientprover och referensintervall togs fram med hjälp av prover från friska hundar och katter. Jämförelsen visade att 9 av 13 analyser hade statistisk signifikant skillnad. Orsaken till det beror troligen på skillnaden av reagens, instrumentens ålder och tid mellan mätningar. Ett nytt referensintervall utarbetades och skiljde sig inte mycket från Thermo Fishers intervall. Vidare validering på grund av liten population rekommenderades. Precisionen för Indiko Plus blev godkänd. Linjäriteten blev icke linjär och berodde troligen på en dålig pipett och bör göras om. / Clinical chemical analyzes has high clinical relevance. In serum/plasma, different parameters can be quantified. Parameters can be proteins, enzymes, ions, metals, lipids, and carbohydrates. With reference intervals, veterinarians can set diagnosis, follow treatment and development of the disease. Parameters are detected with different analysis principles/methods; colorimetry, immunoturbidimetry, enzymatic method and potentiometry. The animal hospital, AniCura, in Hässleholm accept dogs and cats. About 120 chemical analyzes are analyzed every day. AniCura purchased a new instrument, Indiko Plus, which will replace Cobas C111. Indiko Plus provide, more sample positions, 8 new analyzes, increased capacity, and facilitated use. The purpose of this study was to compare the instruments and produce a new reference interval which was compared to the reference interval provided by Thermo Fisher. To verify Indiko Plus, a precision and linearity study were conducted. Blood sampling of dogs and cats was performed by staff at AniCura. The comparison was made with patient samples and the reference intervals were obtained using samples from healthy animals. The comparison showed 9 of 13 analyzes had a statistically significant difference. The reason for this is probably due to the difference in reagents, the age of the instruments and the time between measurements. A new reference interval was developed and did not differ much from the Thermo Fisher interval. Further validation due to low population was recommended. The precision for Indiko Plus was approved. The linearity study shows not linear trend but was likely due to a bad pipette and should be redone.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:hkr-22058
Date January 2021
CreatorsBorg, Johanna
PublisherHögskolan Kristianstad, Fakulteten för naturvetenskap
Source SetsDiVA Archive at Upsalla University
LanguageSwedish
Detected LanguageSwedish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0036 seconds