This thesis focuses on setting the range and efficiency of a water ram pump through experimental measurements in a laboratory. The measurements were carried out on three different constructions of water ram pump, each of the designed and assembled by the author of this thesis himself, to find out whether the weight on the pulsating valve has an influence on the water ram pump efficiency. Further on this thesis aims at the comparison of up to now methods of water transport arrangement used at a summer camp and the usage of the water ram pump and its advantages. The principal of water ram pump originates in hydraulic impact that is being precisely described in a great detail as well. On of the chapters even includes the placement manual for the water ram pump and its overall assembly and connexion. Because the presence of floating debris is inevitable, this thesis also deals with the possibility to solve the incoming water impurities by adding an inflow gating to prevent such problem. This inflow gating has only been designed in a Flow 3D programme to introduce the idea and functions.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:391899 |
Date | January 2019 |
Creators | Růžička, Jakub |
Contributors | Haluza,, Miloslav, Špano, Miroslav |
Publisher | Vysoké učení technické v Brně. Fakulta stavební |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0015 seconds