Return to search

Uso integrado de dados LiDAR e imagens aéreas aplicado na extração de contornos de telhados de edificações / Integration of LiDAR data and aerial imagery for extraction of building roof boundaries

Submitted by GILMAR RENAN KISAKI OLIVEIRA null (renan.kisaki@gmail.com) on 2016-12-20T03:09:27Z
No. of bitstreams: 1
2016_MSc_Gilmar_Renan_Unesp.pdf: 3787156 bytes, checksum: 03bf116759b5ae85b2e5302f167eb985 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-21T19:54:13Z (GMT) No. of bitstreams: 1
oliveira_grk_me_prud.pdf: 3787156 bytes, checksum: 03bf116759b5ae85b2e5302f167eb985 (MD5) / Made available in DSpace on 2016-12-21T19:54:13Z (GMT). No. of bitstreams: 1
oliveira_grk_me_prud.pdf: 3787156 bytes, checksum: 03bf116759b5ae85b2e5302f167eb985 (MD5)
Previous issue date: 2016-02-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Esta dissertação contempla o desenvolvimento de um método que combina os dados LiDAR (Light Detection And Ranging) obtidos por sistema de varredura LASER (Light Amplification by Stimulated Emission of Radiation) e imagens aéreas de uma mesma região a fim de extrair os contornos de telhados de edificações, onde os parâmetros de orientação das imagens são conhecidos. O método proposto neste trabalho pode ser dividido nas seguintes etapas: extração das edificações nos dados LiDAR; extração dos contornos das edificações nos dados LiDAR; e refinamento dos contornos das edificações integrando dados LiDAR e imagens. Primeiramente, as edificações são extraídas dos dados LiDAR, seguida da determinação dos seus pontos de contorno, que por sua vez, são projetados em duas imagens que formam um modelo estereoscópico. Às imagens do par é aplicado o algoritmo de detecção de bordas de Canny com o objetivo de identificar as bordas de edificações. Tendo os contornos dos telhados de edificações (provenientes dos dados LiDAR) projetados nas imagens de bordas, é realizado um procedimento de busca dos pontos de bordas de edificações nas imagens. Com base nos pixels identificados como bordas de edificações e com o propósito de obter uma figura geométrica que represente os contornos, é aplicado o ajuste de retas 2D pelo Método dos Mínimos Quadrados (MMQ) integrado à filtragem de pontos espúrios por meio do teste Tau. Para avaliar o método proposto e implementado foram utilizados dados LiDAR com densidade média de 6,7 pontos/m² e imagens aéreas digitais com GSD de 8 cm. Os resultados obtidos na avaliação dos experimentos mostraram que o método proposto conseguiu extrair os contornos dos telhados, com melhores resultados para edificações isoladas que não possuíam projeção de sombras ou objetos sobre elas, atingindo valores da ordem de 0,97 GSD e 1,80 GSD, para o REMQ em planimetria e altimetria, respectivamente. / This dissertation proposes a methodology to extract building boundary through the integration of LiDAR data and aerial imagery where the image orientation parameters are known. The proposed method can be divided into following steps: building extraction from LiDAR data; building boundary extraction from LiDAR data; and refinement of building boundary through the integration of LiDAR data and optical imaging. Building are first extracted from LiDAR data, then building boundaries are determined in LiDAR data and projected onto the stereo pair of aerial images. These aerial images are results from the application of Canny edge detector in order to identify building boundaries from images. Since the 3D building boundaries (determined from LiDAR data) are projected onto the Canny images, a search mechanism is performed to find the building edge points in these images. A 2D line adjustment by Least Squares Method (LSM) is performed, followed by outlier detection based on Tau Statistical Test, for generating a geometric shape to represent the buildings through the building edge pixels identified. In order to evaluate the proposed approach, LiDAR data with approximate density of 6.7 pts/m² and digital aerial images with GSD around 8 cm were used. The results showed that the proposed method enabled to extract building roof boundaries with best results for isolated buildings without objects or shadow’s projection on them with the root mean square error (RMSE) around 0.97 GSD and 1.80 GSD in planimetry and altimetry, respectively. / CNPq: 130473/2013-8

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/146730
Date29 February 2016
CreatorsOliveira, Gilmar Renan Kisaki [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Galo, Mauricio [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600

Page generated in 0.0026 seconds