The diploma thesis deals with design and comparison of variants of cast-in-place concrete sewage tank made from reinforced concrete and pre-stressed concrete. The layout of sewage tank is rectangular. The tank is in longitudinal way divided into two chambers. The tank is not roofed and is partialy embedded in the ground. The design for ultimate limit state and for service limit state is made for both variants. There is focus on generation and development of cracks in service limit state. For calcuation of internal forces is used model made in software SCIA Engineer, based on finite element method. The reinforced concrete and pre-stressed concrete versions are compared in last part in term of volumes of materials needed. Also there are proposed possible savings.