The aim of this study is designing steel structures with the same geometry, material and soil conditions but in the different countries, and comparing these designs in terms of material savings. According to three steel building codes, namely TS 648, LRFD, Eurocode 3, same structures with various stories (2, 4, 6, 8, and 10) are analyzed and designed. To calculate the design loads, Turkish Earthquake Code 2007 and Turkish Standard 498 (Design Load for Buildings) are utilized when TS 648 is applied. When LRFD is concerned, ASCE Standard 7-05 (Minimum Design Loads for Buildings and Other Structures) and AISC Standard 341-05 (Seismic Provisions for Structural Steel Buildings) are used for calculation of the design loads and earthquake loads. When Eurocode 3 is applied, Eurocode 8 (Earthquake Resistance Code), Eurocode 1 (Actions of Structures) and Eurocode-EN 1990 (Basis of Structural Design) are used in order to determine the design and earthquake loads. Weight of steel used on 1 m² / is almost the same for procedures of LRFD and EC3.
It is important to note that those procedures consider 20 % of material saving compared to TS648.
Identifer | oai:union.ndltd.org:METU/oai:etd.lib.metu.edu.tr:http://etd.lib.metu.edu.tr/upload/3/12610541/index.pdf |
Date | 01 May 2009 |
Creators | Zervent, Altan |
Contributors | Yilmaz, Cetin |
Publisher | METU |
Source Sets | Middle East Technical Univ. |
Language | English |
Detected Language | English |
Type | M.S. Thesis |
Format | text/pdf |
Rights | To liberate the content for public access |
Page generated in 0.0022 seconds