A significant challenge with permanent magnet synchronous motors (PMSMs) is thermal management. Thermal stress can lead to irreversible damage to components, and to enable efficient cooling, a thermal model is needed. In this thesis paper, methods for estimating the hot spot temperature of the windings in PMSMs used in heavy-duty EVs are investigated. The methods include black-box models and lumped parameter thermal network-based models. The results reveal that the implemented models are not sufficient for achieving the desired accuracy, and indicate that more parts of the windings need to be considered.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:liu-197081 |
Date | January 2023 |
Creators | Dahl, Ken |
Publisher | Linköpings universitet, Fordonssystem |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0028 seconds