Wilcox (1990) examined the Type I and Type II error rates for several robust tests of H0: σ12/σ22 = 1 in paired-data designs and concluded that a satisfactory solution does not yet exist. A confidence interval for a ratio of correlated mean absolute deviations is derived and performs well in small sample sizes across realistically nonnormal distributions. When used to test a hypothesis, the proposed confidence interval is almost as powerful as the most powerful test examined by Wilcox.
Identifer | oai:union.ndltd.org:ETSU/oai:dc.etsu.edu:etsu-works-15310 |
Date | 01 January 2003 |
Creators | Bonett, Douglas G., Seier, Edith |
Publisher | Digital Commons @ East Tennessee State University |
Source Sets | East Tennessee State University |
Detected Language | English |
Type | text |
Source | ETSU Faculty Works |
Page generated in 0.0021 seconds