Return to search

Pilares mistos esbeltos em aço preenchidos com concreto, de seção quadrada, em situação de incendio / Slender concrete filled steel columns with square section in fire condition

Orientador: Armando Lopes Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T07:34:07Z (GMT). No. of bitstreams: 1
Sant'Anna_MatheusSarcedo_M.pdf: 3508355 bytes, checksum: fb97535d7c8b7b794c3114773da93628 (MD5)
Previous issue date: 2009 / Resumo: O desenvolvimento técnico e científico fez surgir sistemas estruturais mistos, entre eles os pilares mistos preenchidos, com grande aplicação em edifícios altos. Como a estrutura mista tem um bom comportamento estrutural aliado a uma redução de custos com materiais, mão-de-obra e tempo de execução, ela tem tido um crescente avanço na utilização em países europeus, americanos e asiáticos. Buscando contribuir com o avanço tecnológico estrutural, este trabalho analisou experimentalmente o comportamento estrutural de pilares mistos esbeltos preenchidos axialmente comprimidos, em situação de incêndio, obtendo a influência de variáveis como: nível de carga e resistência à compressão do concreto de preenchimento. Foram analisados pilares esbeltos de seção quadrada preenchidos com concreto de resistência usual e alta resistência, submetidos a diferentes níveis de carregamentos axiais, a saber 30, 50 e 70% da carga última de ruptura. Os resultados dos tempos de resistência ao fogo foram comparados com os resultados previstos pelo EUROCODE 4 (prEN 1994-1-2:2002) e também, com resultados disponíveis na literatura. Verificou-se, ao final do trabalho, um aumento no tempo de resistência ao fogo de pilares mistos preenchidos em comparação com pilares de aço sem preenchimentos. / Abstract: The technical and scientific development has given origin to mixed structural systems, including the columns filled with great application in high buildings. As the mixed structure has a good structural behavior combined with a reduction of costs of materials, manpower and time of execution, it has had a breakthrough in use in European, American and Asian countries. Seeking to contribute to the structural technological advancement, this study experimentally examined the structural behavior of slender columns filled, axially compressed, on fire, getting the influence of variables such as level of load and resistance to compression of the concrete to be filled. We analyzed slender columns of square section filled with concrete of usual resistance and high resistance, submitted to different levels of axial loads, namely 30, 50 and 70% of the last load of collapse. The results of time for fire resistance were compared to results expected by EUROCODE 4 (prEN 1994-1-2:2002) and with results available in the literature. It was verified, at the end of work, an increase in time of fire resistance of columns filled in comparison with steel pillars without fills. / Mestrado / Estruturas / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258723
Date13 August 2018
CreatorsSant' Anna, Matheus Sarcedo
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreno Junior, Armando Lopes, 1964-, Junior, Armando Lopes Moreno, Requena, João Alberto Venegas, Junior, Carlito Calil
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format178 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds