Thesis (M. Eng.)--Harvard-MIT Division of Health Sciences and Technology, 2008. / Includes bibliographical references (leaves 51-56). / Cell-based high-throughput screening is emerging as a disruptive technology in drug discovery; however, massively parallel electrical assaying of neurons and cardiomyocites has until now been prohibitively expensive. To address this limitation, we developed a scalable, all-organic 3D microelectrode array technology. The cheap, disposable arrays would be integrated into a fixed stimulation and imaging setup, potentially amenable to automated handling and data analysis. A combination of activity-dependent plasticity, made possible by independent control of up to 64 stimulating electrodes, and, eventually, of substrate chemical patterning would be employed to constrain the neuronal culture network connectivity. In order to ensure longterm survival of the cultures, a bottom feeder layer of glial cells would be grown. In addition to high-throughput screening application, the polymeric microelectrode arrays and integrated stimulation systems were designed to allow the long-term study of synaptic plasticity, combining excellent long-term culture capabilities with a unique ability to independently control each electrode stimulation pattern. The resulting activity could be monitored optically, e,g, with calcium or voltage sensitive dyes, and the images could be stored and processed (possibly even in real time) within the same environment (LabView) as the stimulator. To fabricate the polymeric microelectrode array, we prepare a multilayered mask substrate, by reversibly bonding together two sheets of implant-grade polydimethylsiloxane (PDMS) sheets, with or without a glass coverslip between them. Thanks to PDMS self-adhesive properties the various layers are held together stably but reversibly. The mask is then laser-patterned, using either a standard CO2 laser or a 193 nm excimer laser. / (cont.) The mask can then be adhered onto a glassy carbon or ITO electrode, and polypyrrole, doped with either hyaluronic acid or sodium dodecylbenzesulfonic acid, can be electrodeposited through it. Finally, the construct is removed from the deposition bath and the upper, sacrificial mask layer carefully peeled away. This fabrication method allows exquisite control overall 3D electrode geometry, is suitable to produce structures between one and several hundred micrometers in diameter, either filled or tubular, and scales extremely well, so that, for example, 384 by 64 electrodes arrays can be patterned in just a few minutes and grown in the same time as a single array. / by Giovanni Talei Franzesi. / M.Eng.
Identifer | oai:union.ndltd.org:MIT/oai:dspace.mit.edu:1721.1/43878 |
Date | January 2008 |
Creators | Talei Franzesi, Giovanni |
Contributors | Martha Constantine-Paton and Ian W. Hunter., Harvard University--MIT Division of Health Sciences and Technology., Harvard University--MIT Division of Health Sciences and Technology. |
Publisher | Massachusetts Institute of Technology |
Source Sets | M.I.T. Theses and Dissertation |
Language | English |
Detected Language | English |
Type | Thesis |
Format | 56 leaves, application/pdf |
Rights | M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission., http://dspace.mit.edu/handle/1721.1/7582 |
Page generated in 0.002 seconds