Made available in DSpace on 2014-06-11T19:29:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-04-03Bitstream added on 2014-06-13T19:38:06Z : No. of bitstreams: 1
garcia_g_me_araiq.pdf: 720834 bytes, checksum: e19349ecd4bfbb9a08ff4ee78015990a (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Entre os compostos poluentes mais comuns presentes em ambientes abertos e fechados, o ozônio é considerado um dos mais agressivos à saúde humana, e de acordo com estudos realizados pela CETESB sua tendência geral no ambiente tem sido de aumentar sua concentração. Este trabalho descreve o desenvolvimento de novo amostrador passivo para determinação de ozônio troposférico em estudos ambientais. O amostrador passivo construído possui características que possibilitam utilização de menor tempo de amostragem, somente 8 horas. Seu desempenho foi avaliado pela comparação com método ativo, através de amostragens acompanhadas com analisador de ozônio. Os desvios de exatidão e precisão foram respectivamente ± 10,2 % e ± 8,6 %, e os limites de detecção e quantificação foram respectivamente 3,8 ppb e 8,6 ppb. A curva analítica construída apresentou coeficiente angular de 0,88 e coeficiente de correlação (r) de 0,957. O amostrador foi então empregado em estudos de mapeamentos e monitoramentos simultâneos da concentração de ozônio, em escala municipal, com locais de amostragem na cidade de Araraquara, e em escala regional, abrangendo ampla área territorial, com um local de amostragem em cada cidade: Bauru, São José do Rio Preto, Presidente Prudente, Sorocaba e Ribeirão Preto. Após 10 meses de amostragens os resultados comprovaram bom desempenho do amostrador em mapeamentos e monitoramentos simultâneos, identificando locais de pico de concentração do poluente e avaliando o perfil da variação da concentração do poluente ao longo do período do estudo. Este tipo de trabalho pode ajudar a entender melhor o problema e servir como parâmetro importante para auxiliar a CETESB a incluir novos centros de monitoramento, e também a pesquisadores a direcionar suas pesquisas na busca de entendimento mais abrangente do problema inclusive sobre sua ação na saúde da população. / Among the most common pollutants in open and closed environments, ozone is considered one of the most aggressive to human health, according to studies performed by CETESB its general trend in the environment the increasing of its concentration. This paper describes the development of new passive sampler for determination of tropospheric ozone in environmental studies. The passive sampler constructed has features that allow use of small time of sampling, only 8 hours. Its performance was evaluated by comparison with active method, by an ozone analyzer monitoration. The deviations of accuracy and precision were respectively ± 10.2% and ± 8.6%, and the limits of detection and quantification were respectively 3.8 ppb and 8.6 ppb. The analytical curve showed slope constructed of 0.88 and correlation coefficient (r) of 0,957. The sampler was then used in studies of simultaneous mapping and monitoring the concentration of ozone, at municipal level, with sampling locations in the city of Araraquara, and at the regional scale, covering large geographical area with a place of sampling in each city: Bauru , São José do Rio Preto, Presidente Prudente, Ribeirão Preto and Sorocaba. After 10 months the sampling results confirmed the good performance of the sampler in mapping and monitor simultaneously, identifying peak concentration local of the pollutant and evaluating the profile of variation of the concentration of the pollutant over the period of study. This type of work can help better understand the problem and can be an important parameter to help CETESB include new centers for monitoring, and the researchers to direct further studies toward the problem understanding, including its action on the health of population.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/97808 |
Date | 03 April 2009 |
Creators | Garcia, Gabriel [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Cardoso, Arnaldo Alves [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 78 f. : il. |
Source | Aleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | -1, -1 |
Page generated in 0.0052 seconds