Return to search

The six phase rectifier as a power source for operating DC motors

It can definitely be stated that the results of the experiments show that almost no appreciable adverse effects on the test motor result from six phase rectifier operation, The efficiency was unaffected by rectifier operation, The temperature rise with rectifier operation was roughly within 5°C of that obtained with DC generator input, The commutation was not adversely affected when using the rectifier, These statements apply even when the rectifier is operated at half voltage, a condition giving very much more ripple than the full voltage ripple. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/40945
Date06 February 2013
CreatorsEbert, Harry K., Jr.
ContributorsElectrical Engineering, Murray, W. A., Whittemore, John A., Pardue, Louis A.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
LanguageEnglish
Detected LanguageEnglish
TypeThesis, Text
Format114 leaves, BTD, application/pdf, application/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationOCLC# 24841341, LD5655.V855_1953.E247.pdf

Page generated in 0.0014 seconds