The purpose of this research was to investigate the influence of height, crosssection and metal alloy in the mechanical act of teardrop loops used in incisors
retraction and in en masse retraction of incisors and canines, aiming analyze the mechanical behavior of these loops in relation to optimum forces presented in the
literature. Two hundred and forty loops were submitted to a tensile load on the testing machine considered heights of 6mm, 8mm and 10mm; cross-sections of 0.018in.x
0.025in and 0.019in.x 0.025in and wire materials of stainless steel and beta-titanium alloys. It was obtained magnitudes of horizontal force (N) and load-deflection (N/mm) for each loop across activations of 0.5mm, 1mm, 1.5mm, 2mm and 2.5mm. The results showed that height (p<0.01), cross-section and metal alloy (p<0.05) were
considered significant factors with reference to horizontal force and load-deflection. There was no influence of one factor but a combination of these trying to achieve very light forces. This study suggest that is necessary a large orthodontic biomechanics knowledge with respect to loops design used in incisors retraction and
in en masse retraction of incisors and canines, selecting adequate height, crosssection and metal alloy. / O objetivo desta pesquisa foi investigar os efeitos da altura, secção transversal e tipo de liga no desempenho mecânico de alças confeccionadas em forma de gota, indicadas para a retração de incisivos e para a retração em massa de
incisivos e caninos, buscando avaliar o comportamento das mesmas em relação às magnitudes de força ótima existentes na literatura. Foram submetidas a um ensaio mecânico 240 alças, considerando as alturas de 6mm, 8mm e 10mm; as seções transversais de 0.018 x 0.025 e de 0.019 x 0.025 e as ligas de aço inoxidável e beta-titânio (TMA). Foram obtidos valores de força horizontal (N) e carga-deflexão (N/mm) para cada alça mediante ativações de 0.5mm, 1mm, 1.5mm, 2mm e 2.5mm. Os resultados mostraram que a altura (p<0.01), a secção transversal e a liga (p<0.05) foram consideradas fatores significativos na força horizontal e cargadeflexão
gerada. Não houve influência de um fator sobre os demais, mas sim, uma combinação destes, buscando atingir forças muito leves. Este estudo sugere que é necessário amplo conhecimento da biomecânica ortodôntica na confecção de alças direcionadas para a retração dos dentes anteriores, selecionando adequadamente a altura, a secção transversal e a liga.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufsm.br:1/6057 |
Date | 22 January 2010 |
Creators | D'ornellas, Mauro Cordeiro |
Contributors | Grehs, Renésio Armindo, Ferrazzo, Vilmar Antonio, Closs, Luciane Quadrado |
Publisher | Universidade Federal de Santa Maria, Programa de Pós-Graduação em Ciências Odontológicas, UFSM, BR, Odontologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFSM, instname:Universidade Federal de Santa Maria, instacron:UFSM |
Rights | info:eu-repo/semantics/openAccess |
Relation | 400200000000, 400, 300, 300, 300, 300, c078af30-5acd-4f62-9f7d-40682b15ce4b, 6e652a95-0aab-4251-994f-9312ecfde2d9, 97872177-64e3-4594-93ee-ce372229dd24, 80504426-3866-4e0c-8d95-fdf4e3aaaccd |
Page generated in 0.0056 seconds