Return to search

An?lise da ativa??o e desempenho muscular de membros inferiores em indiv?duos com insufici?ncia venosa cr?nica durante teste de eleva??o do calcanhar

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-06-02T22:17:33Z
No. of bitstreams: 1
NathalieCortezBezerraDeMedeiros_DISSERT.pdf: 1947192 bytes, checksum: 191bf33e4eb1f0d2955ff10f51d47523 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-06-08T20:06:08Z (GMT) No. of bitstreams: 1
NathalieCortezBezerraDeMedeiros_DISSERT.pdf: 1947192 bytes, checksum: 191bf33e4eb1f0d2955ff10f51d47523 (MD5) / Made available in DSpace on 2017-06-08T20:06:08Z (GMT). No. of bitstreams: 1
NathalieCortezBezerraDeMedeiros_DISSERT.pdf: 1947192 bytes, checksum: 191bf33e4eb1f0d2955ff10f51d47523 (MD5)
Previous issue date: 2017-03-28 / Introdu??o: A falha na fun??o da bomba muscular da panturrilha ? considerada a principal causa da insufici?ncia venosa cr?nica (IVC) e a hipertens?o venosa prolongada, leva ao enfraquecimento da musculatura da panturrilha. A avalia??o espec?fica dessa musculatura pode ser feita de diferentes formas, entre elas a utiliza??o do teste de eleva??o do calcanhar (TEC). Atualmente, v?rios protocolos foram desenvolvidos para a realiza??o do TEC em diferentes popula??es, sem uma padroniza??o bem detalhada. Objetivos: Primariamente avaliar a confiabilidade e reprodutibilidade tanto intra quanto inter-avaliadores do TEC em adultos saud?veis, de dois diferentes protocolos com diferentes est?mulos: auto-cadenciado (TECAC) e externamente cadenciado (TECEC); Secundariamente, avaliar o desempenho e a atividade el?trica dos m?sculos dos membros inferiores durante a realiza??o do TECEC em sujeitos com IVC comparando com indiv?duos saud?veis pareados. M?todos: Dois estudos foram realizados e ambos foram do tipo observacional, de car?ter transversal. Para o Estudo 1, dois protocolos do TECAC e TECEC foram realizados em sujeitos jovens e saud?veis. Para o Estudo 2, foram recrutados sujeitos com idade entre 35 e 65 anos, com diagn?stico cl?nico de IVC para realiza??o do TECEC associado ? Eletromiografia de Superf?cie (EMGs). Resultados: No estudo 1, 33 indiv?duos saud?veis foram recrutados (16H), com idade de 23,03 anos (?2,71). Observamos que o TECAC obteve um melhor resultado tanto no que diz respeito ao desempenho (53,01 eleva??es) quanto ? reprodutibilidade relativa inter-avaliador (CCI=0,77) e, o TECEC obteve melhor reprodutibilidade intra-avaliador (CCI=0,69). Foi observado que ao final da realiza??o de ambos os testes houve aumento dos sintomas de fadiga (p<0,01); entretanto, com manuten??o do desempenho de eleva??es de calcanhar nos tr?s TECAC (p=0,76) e diminui??o do desempenho no TECEC quando comparados T1, T2 e T3 (p<0,01). No Estudo 2, foram recrutados 44 sujeitos com IVC, dos quais 17 atingiram todos os crit?rios de inclus?o e compuseram a amostra do Grupo IVC, versus 17 sujeitos saud?veis pareados por idade, sexo e IMC que compuseram o Grupo Controle. Houve diferen?a significante na compara??o intergrupo do desempenho do TECEC (p<0,01) e tamb?m na compara??o intergrupo do tempo gasto para realiza??o do TECEC (p<0,05). A plantiflex?o no membro inferior direito foi significativamente menor (p<0,05) no Grupo IVC. Para avalia??o da atividade el?trica, o TECEC foi dividido em quatro momentos (25%, 50%, 75% e 100%). Na avalia??o da atividade el?trica muscular durante o TECEC, foram encontradas diferen?as significantes nos momentos 50% e 75% (p<0,05) do m?sculo tibial anterior direito e nos momentos 25% e 50% (p<0,05) do m?sculo tibial anterior esquerdo. Conclus?o: Nossos resultados do Estudo 1 demonstram que ambos os TEC (auto-cadenciado e externamente cadenciado) podem ser utilizados para fornecer resultados de desempenho muscular. O TECEC potencialmente determina uma maior e mais intensa atividade muscular e o TECAC demonstrou melhor reprodutibilidade e maior concord?ncia, quando avaliado o desempenho nos tr?s momentos. Em rela??o ao Estudo 2, ? poss?vel observar que os indiv?duos com IVC apresentam um desempenho inferior no TECEC comparados a sujeitos saud?veis, com menor atividade el?trica muscular em tibial anterior bilateralmente j? em est?gios iniciais da doen?a. / Background: Failure of calf muscle pump function is considered a major cause of venous insufficiency (CVI) and prolonged venous hypertension leads to weakening of the calf muscles. The evaluation can be done from different forms, from a heel lift test (TEC). Currently, several protocols have been developed for an ECT test in different populations, without a very detailed standardization. Objectives: Firstly to evaluate the reliability and reproducibility of intra-r inter-raters in healthy adults, from two different protocols with different stimuli: self-paced (TECAC) and externally cadenced (TECEC); secondarily, to evaluate the performance and electrical activity of lower limb muscles during an TECEC in subjects with CVI compared with healthy paired subjects. Methods: Two studies were performed and both were of the observational type, with a transversal character. For Study 1, two TECAC and TECEC protocols were performed on healthy young subjects. For Study 2, subjects with ages between 35 and 65 years old were recruited, with a clinical diagnosis of CVI to perform TECEC associated with Surface Electromyography (EMGs). Results: In study 1, 33 healthy subjects were recruited (16H), aged 23.03 years (? 2.71). We observed that the TECEC obtained a better result both in terms of performance (53.01 elevations) and relative inter-rater reproducibility (ICC = 0.77) and the TECEC obtained better intra-rater reproducibility (ICC = 0, 69). It was observed that at the end of both tests there was an increase in fatigue symptoms (p <0.01); (P = 0.76) and decreased performance in the TECEC when compared to T1, T2 and T3 (p <0.01). In Study 2, 44 subjects with CVI were recruited, of whom 17 met all inclusion criteria and composed the sample of Group IVC versus 17 healthy subjects matched for age, sex and BMI who composed the Control Group. There was a significant difference in the intergroup comparison of the TECEC performance (p <0.01) and also in the intergroup comparison of the time spent to perform the TECEC (p <0.05). The flexure in the right lower limb was significantly lower (p <0.05) in Group IVC. For evaluation of electrical activity, the TECEC was divided into four moments (25%, 50%, 75% and 100%). In the evaluation of the muscular electrical activity during the TECEC, significant differences were found in the moments 50% and 75% (p <0.05) of the right anterior tibial muscle and moments 25% and 50% (p <0.05) of the muscle Anterior tibialis. Conclusion: Our results from Study 1 demonstrate that both (self-paced and externally paced) ECT can be used to provide muscle performance results. The TECEC potentially determines a greater and more intense muscular activity and the TECAC demonstrated better reproducibility and greater agreement, when evaluated the performance in the three moments. Regarding Study 2, it is possible to observe that individuals with CVI present inferior performance in the TECEC compared to healthy subjects, with lower muscular electrical activity in the anterior tibial bilaterally already in the initial stages of the disease.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/23439
Date28 March 2017
CreatorsMedeiros, Nathalie Cortez Bezerra de
Contributors02548515923, Sousa, Catarina de Oliveira, 01214947484, http://lattes.cnpq.br/5522647106933904, Pereira, Danielle Aparecida Gomes, 00536211663, http://lattes.cnpq.br/4666417473315827, Fregonezi, Vanessa Regiane Resqueti
PublisherPROGRAMA DE P?S-GRADUA??O EM FISIOTERAPIA, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds