Return to search

Pesquisa do Linfonodo Sentinela em Pacientes portadoras de CÃncer de Mama localmente avanÃado e submetidas à quimioterapia neoadjuvante / Linfonodo sentry in cancer in breast local advanced pÃs-quimioterapia neoadjuvante

CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / estudar o linfonodo sentinela em pacientes portadoras de cÃncer na mama localmente avanÃado e que foram submetidos a quimioterapia neoadjuvante, compararando-o com os linfonodos axilares nÃo-sentinelas. Verificar a taxa de identificaÃÃo do linfonodo sentinela nestas pacientes, assim como estimar a sensibilidade, especificidade, falso-negativo, valor preditivo negativo e acurÃcia do mÃtodo. Metodologia: estudo transversal de validaÃÃo de teste diagnÃstico, envolvendo 34 pacientes oriundas do AmbulatÃrio da Maternidade-Escola Assis Chateaubriand. As pacientes portadoras de cÃncer na mama localmente avanÃado foram submetidas a quimioterapia neoadjuvante e aquelas que apresentaram axila clinicamente negativa para metÃstase de cÃncer de mama foram submetidas a biopsia do linfonodo sentinela e linfadenectomia axilar, utilizando administraÃÃo subareolar de azul patente, e este, apÃs sua identificaÃÃo, foi estudado mediante o exame de citologia de contato e parafina e comparado com conteÃdo linfÃtico axilar nÃo-sentinela. Realizada anÃlise descritiva e anÃlise dos testes utilizando teste t de Student, as proporÃÃes dos testes foram consideradas significativamente diferentes quando a probabilidade de estas serem semelhantes foi menor ou igual a 0,05. Resultados: Quando foi testada a citologia de contato intra-operatÃrio e parafina linfonodo sentinela e padrÃo-ouro os linfonodos sentinelas e nÃo-sentinelas, a taxa de identificaÃÃo do linfonodo sentinela foi de 85,3%. A sensibilidade foi de 84,62% e a especificidade de 100%. O valor preditivo negativo de 87,99% e taxa de falso-negativo de 12,01%. A acurÃcia foi de 92,77%. Dado observado na amostra foi a diferenÃa significativa do nÃmero mÃdio do total de linfonodos observados entre o grupo de pacientes com tempo de intervenÃÃo cirÃrgica Ãtimo p=0,037. Quando foi testada apenas a citologia de contato intraoperatÃria do linfonodo sentinela e padrÃo-ouro, a parafina dos linfonodos sentinelas e nÃo-sentinelas a sensibilidade foi de 62,50%, a especificidade de 100%, valor preditivo negativo de 75,04%, falso-negativo de 24,96% e acurÃcia de 82,38%. ConclusÃo: a citologia de contato intraoperatÃrio do linfonodo sentinela para pacientes com cÃncer de mama localmente avanÃados com axila clinicamente negativa apÃs quimoterapia neoadjuvante apresenta baixa sensibilidade e taxa de falso-negativo elevada. / Aims: investigating sentinel lymph node in patients with locally advanced breast cancer whom were administered neoadjuvant chemotherapy, by contrast to non-sentinel axillary lymph nodes. Verifying the identification of sentinel lymph node rate in these patients, as well as estimating methodâs sensibility, specificity, false-negative and accuracy. Methodology: transversal study for validation of a diagnostic test, with 34 patients from Maternidade-Escola Assis Chateaubriandâs ambulatory. The locally advanced breast cancer patients were treated with neoadjuvant chemotherapy, and the ones with cancer metastasis clinically negative axilla were submitted to sentinel lymph node biopsy and axillary lymphadenectomy, using subareolar patent blue, and, after its identification, it was studied with contact cytology and paraffin and it was compared with non-sentinel axillary lymph content. The descriptive analysis of tests used Studentâs t-test, and tests proportions were considered significantly different when their similarity possibility was less or equal to 0.05. Results: When intraoperatory contact cytology study, paraffin sentinel lymph node and gold standar, sentinel and non-sentinel lymph nodes, the sentinel lymph node identification rate was 85.3%. Sensibility was 84.62%, and specificity was 100%. The predictive negative value was 87.99%, and the false-negative rate was 12.01%. Accuracy rate was 92.77%. The study points the significant difference of total lymph nodes mean number observed among the group with optimal time of surgical intervention p=0.037. When only the intraoperatory contact cytology of sentinel lymph node and gold pattern, the paraffin of sentinel and non-sentinel lymph nodes, sensibility was 62.50%, specificity 100%, predictive negative value 75.04%, false-negative 24.96%, and accuracy 82.38%. Conclusion: intraoperatory contact cytology of sentinel lymph node to locally advanced breast cancer patients with clinically negative axilla after neoadjuvant chemotherapy presents low sensibility and high false-negative rates.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:1066
Date27 December 2007
CreatorsPaulo Henrique Walter de Aguiar
ContributorsLuiz Gonzaga Porto Pinheiro, EugÃnio Pacelli de Barreto Teles, Silvia Bomfim HyppÃlito
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Tocoginecologia, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds