Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-12-08T12:31:51Z
No. of bitstreams: 1
JESSE JAMES GOMES DA SILVA M.pdf: 5503633 bytes, checksum: 2dcecbb52b0e542ca9f3a3a3c2f47fd6 (MD5) / Made available in DSpace on 2017-12-08T12:31:51Z (GMT). No. of bitstreams: 1
JESSE JAMES GOMES DA SILVA M.pdf: 5503633 bytes, checksum: 2dcecbb52b0e542ca9f3a3a3c2f47fd6 (MD5)
Previous issue date: 1995-10 / Esse trabalho concentrou-se na realização de inspeções de amostras, por radiografía com nêutrons, para detecção de defeitos. Como fonte de nêutrons térmicos foi utilizado o reator Argonauta do Instituto de Engenharia Nuclear/CNEN, em cuja coluna térmica externa foi instalado um dispositivo experimentai para realização de Ensaios Não Destrutivos por neutrongrafia térmica. Os materiais estudados foram a liga de alumínio AA 7075 utilizada na indústria aeronáutica e o concreto estrutural de alta resistência utilizado na engenharia civil Amostras da liga de alumínio foram inspecionadas com o objetivo de avaliar a capacidade do dispositivo neutrongráfico instalado para detecção de corrosões ocultas, na forma de pites e de esfoliação. A inspeção de amostras de concreto de alta resistência, obtidas de corpos de prova especificados, enfocou o exame de sua estrutura interna e a detecção de microfissuras eventualmente provocadas por aplicações de cargas externas. Uma solução aquosa de nitrato de gadolinio foi utilizada como agente contrastante com o objetivo de melhorar o contraste radiográfico de áreas com corrosões e de falhas, nos materiais estudados. Da análise das imagens obtidas, pode-se concluir que o sistema neutrongráfico experimental foi capaz de realizar satisfatoriamente as inspeções propostas. / This work shows the aplication of Neutron Radiography (NR) as a Non Destructive Testing technique for inspection of materials. Detection of defects in samples such as those from aircraft structures made of AA 7075 aluminum alloy, as well as those from structural concrete, were performed with the neutron radiography experimental device adapted in the external thermal column of the Argonaut reactor of Nuclear Engineering Institute, IEN/CNEN. Application of an aqueous solution of gadolinium nitrate as a contrast agent in samples of AA 7075 aluminum alloy for enhancement of detection of corrosion, as the pitting and exfoliation, is shown. The same contrast agent was used to improve the detection capability of flaws, such as microcracks and voids in concrete. From the sharpness of the neutron radiography images we can conclude trat the NR experimental device is able to make the proposed inspections.
Identifer | oai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/2005 |
Date | 10 1900 |
Creators | Silva, Jesse James Gomes da, Instituto de Engenharia Nuclear |
Contributors | Alves, Rex Nazaré, Crispim, Verginia Reis |
Publisher | Instituto de Engenharia Nuclear, Programa de Pós-Graduação em Engenharia Nuclear, IEN, Brasil, Instituto Militar de Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0024 seconds