Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-20T17:31:53Z
No. of bitstreams: 1
wellingtoncarlosdaconceicao.pdf: 2412660 bytes, checksum: 31c07135427924fe90166a943adbbdd7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Renata, somente a primeira letra de cada palavra chave é que deve ser em maiúsculo. Não corrigi esta para só para me lembrar de te falar. on 2016-07-02T11:26:49Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-04T10:15:18Z
No. of bitstreams: 1
wellingtoncarlosdaconceicao.pdf: 2412660 bytes, checksum: 31c07135427924fe90166a943adbbdd7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:11:09Z (GMT) No. of bitstreams: 1
wellingtoncarlosdaconceicao.pdf: 2412660 bytes, checksum: 31c07135427924fe90166a943adbbdd7 (MD5) / Made available in DSpace on 2016-07-13T16:11:09Z (GMT). No. of bitstreams: 1
wellingtoncarlosdaconceicao.pdf: 2412660 bytes, checksum: 31c07135427924fe90166a943adbbdd7 (MD5)
Previous issue date: 2012-08-02 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho apresenta uma metodologia alternativa para o atendimento da
restrição associada à vazão mínima obrigatória no problema de planejamento da
operação de médio prazo de sistemas hidrotérmicos interligados. Atualmente, a
metodologia oficial adotada no Setor Elétrico Brasileiro consiste na utilização de uma
variável de folga associada a esta restrição.
Neste trabalho é proposta uma estratégia visando manter os reservatórios operando
dentro de níveis seguros associada à utilização de uma variável de folga. Para tanto foi
criada uma curva de energia armazenável mínima, que fornece a informação sobre os
níveis mínimos de armazenamento dos reservatórios equivalentes, de tal forma que os
mesmos sejam capazes de suprir as perdas e a vazão mínima obrigatória. As duas
metodologias são comparadas e os resultados das simulações mostraram que a
formulação proposta leva a uma diminuição no valor esperado de déficit de vazão
mínima obrigatória. / This work presents an alternative methodology to meet the constraint associated with
mandatory minimum outflow in the problem of long-term operation planning of
hydrothermal interconnected systems. Currently, the official methodology adopted in
the Brazilian Electric Sector is the use of a slack variable associated with this
restriction.
This work proposes a strategy to keep the reservoirs operating within safe levels
associated with use of a slack variable. For this, is constructed a storable energy curve
minimum, providing information about the minimum levels of storage reservoirs
equivalent, so that the reservoirs are able to supply the losses and the mandatory
minimum outflow. The two methodologies are compared and the simulation results
showed that the proposed formulation leads to a decrease in the expected value of
deficit minimum flow.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1954 |
Date | 02 August 2012 |
Creators | Conceição, Wellington Carlos da |
Contributors | Marcato, André Luís Marques, Belati, Edmarcio Antonio, Passos Filho, João Alberto |
Publisher | Universidade Federal de Juiz de Fora, Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds