The diploma thesis addresses the topic of optical measurements of flange joints during tightening and thermal loading. Commercially available optical systems with decreasing invasiveness were compared in opportunity which offer to an industrial environment. Various conditions are evaluated in 3D (scanning, DIC) as well as in 2D (DIC). The data for evaluation of sensitivity and system accuracy together with the evaluation of the data range were obtained by the measurement. Data evaluation showed the same accuracy for 2D and 3D system and the possibility of quality inspection of the joint by assessing the inspection dimensions in operation.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:444269 |
Date | January 2021 |
Creators | Schmidtová, Markéta |
Contributors | Mendřický, Radomír, Hurník, Jakub |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |