Submitted by Marcia Silva (marcia@latec.uff.br) on 2016-10-10T18:53:23Z
No. of bitstreams: 1
Dissert Adriana Vidal França de Carvalho.pdf: 2829879 bytes, checksum: 20647d41336cf9b355d364ab38963b35 (MD5) / Approved for entry into archive by Biblioteca da Escola de Engenharia (bee@ndc.uff.br) on 2017-01-26T13:49:06Z (GMT) No. of bitstreams: 1
Dissert Adriana Vidal França de Carvalho.pdf: 2829879 bytes, checksum: 20647d41336cf9b355d364ab38963b35 (MD5) / Made available in DSpace on 2017-01-26T13:49:06Z (GMT). No. of bitstreams: 1
Dissert Adriana Vidal França de Carvalho.pdf: 2829879 bytes, checksum: 20647d41336cf9b355d364ab38963b35 (MD5)
Previous issue date: 2016-04-18 / O impacto na qualidade do ar causado pela emissão de poluentes atmosféricos tem sido um problema ambiental crescente, especialmente nos centros urbanos e nas áreas industriais. O ozônio, formado por reações fotoquímicas, é um dos principais componentes do smog fotoquímico. Devido às suas características oxidantes ele é prejudicial à saúde e ao meio ambiente. Por ser um poluente secundário, o controle dos níveis de ozônio na troposfera deve ser realizado a partir da redução dos seus principais precursores: COVs e óxidos de nitrogênio. Refinarias de petróleo são importantes fontes de COVs, especialmente de emissões fugitivas de componentes de linhas de processo e, portanto, são fontes onde há potencial para reduzir estas emissões. Além disso, as licenças ambientais das refinarias também exigem a redução de emissões fugitivas de COVs. A metodologia LDAR, baseada no uso de um analisador portátil para identificação de vazamentos em componentes de linhas de processo, vem sendo utilizada nos Estados Unidos desde a década de 70 para a redução das emissões fugitivas de COVs em refinarias de petróleo. É uma metodologia bastante intensiva em mão de obra e tem custo elevado, uma vez que exige o monitoramento individual de milhares de componentes existentes em uma planta industrial para a detecção de vazamentos. Porém, estudos mostram que o controle com foco nos grandes vazamentos permite uma redução mais efetiva das emissões fugitivas e com menor custo. A metodologia Smart LDAR, que consiste no uso de imagem ótica de infravermelho para visualização de gases, permite a identificação dos grandes vazamentos, que são os que mais contribuem para as emissões fugitivas, sem que haja necessidade de medição de todos os componentes das linhas de processo. O objetivo desta pesquisa é avaliar as metodologias LDAR (Leak Detection and Repair) e Smart LDAR, utilizadas para o controle de emissões fugitivas de compostos orgânicos voláteis (COVs) em refinaria de petróleo, utilizando o conceito de custo-efetividade. Os resultados obtidos a partir das avaliações realizadas mostraram que a metodologia Smart LDAR tem melhor relação custo efetividade para o controle de emissões fugitivas de COVs em comparação à metodologia LDAR convencional / The impact on air quality caused by air pollutants emissions has proven to be a growing environmental problem, mainly at urban centers and industrial areas. The ozone, formed through photochemical reactions, is the photochemical smog’s major component. Due its oxidizing characteristics, it is harmful to the healthy and to the environment. Due to de fact to be a secondary pollutant, the ozone control in the troposphere must be achieved by reducing emissions from its main precursors: VOCs and nitrogen oxides. Petroleum refineries are significant sources of VOCs, especially of fugitive emissions from process lines’ components, so they are sources with potential to reduce these emissions. Furthermore, the petroleum refineries’ environmental licenses also demand the reduction of VOCs’ fugitive emissions. The LDAR methodology, which is based on the application of a portable analyzer to identify leaks in process lines’ components, has been used in the US since the 70s to reduce VOCs’ fugitive emissions in petroleum refineries. This methodology is quite intensive hand labor and costly, since an industrial plant has thousands of components that must be measured individually to detect leaks. However, studies show that the control focusing on large leaks allows the reduction of fugitive emissions more effectively and with low costs. The methodology known as Smart LDAR, which uses infrared optical image for gas leaks view, has the potential to identify great leaks, that most contribute to the fugitive emissions, without requirement to measure all process lines’ components. The purpose of this research is evaluate the methodologies LDAR (Leak Detection and Repair) and Smart LDAR, used to control volatile organic compounds’ (VOCs) fugitive emissions in petroleum refineries, using the concept of cost-effective analysis. The results obtained from the evaluations of this study showed that the Smart LDAR methodology has the best cost effective relation to control fugitive emissions compared to the LDAR conventional methodology
Identifer | oai:union.ndltd.org:IBICT/oai:https://app.uff.br/riuff:1/2800 |
Date | 18 April 2016 |
Creators | Carvalho, Adriana Vidal França de |
Contributors | Barros, Sergio Ricardo da Silveira, Oliveira, Saulo Barbara de, França, Sergio Luiz Braga |
Publisher | Universidade Federal Fluminense, Niterói |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFF, instname:Universidade Federal Fluminense, instacron:UFF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds