Return to search

Modelo elétrico de supressor de surto de ZnO com ampla faixa de operação.

Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-06-06T13:59:11Z
No. of bitstreams: 1
VALDEMIR DA SILVA BRITO - TESE (PPGEE) 2016.pdf: 24283842 bytes, checksum: 359b3901fbb8d95187c4a580e505a74f (MD5) / Made available in DSpace on 2018-06-06T13:59:11Z (GMT). No. of bitstreams: 1
VALDEMIR DA SILVA BRITO - TESE (PPGEE) 2016.pdf: 24283842 bytes, checksum: 359b3901fbb8d95187c4a580e505a74f (MD5)
Previous issue date: 2016-10-07 / Capes / Este trabalho propõe um modelo elétrico de supressor de surto de ZnO que o representa com exatidão nas três regiões de operação, em uma ampla faixa de frequência e amplitude. O Modelo Elétrico Proposto (MEP) foi validado a partir de um banco de dados, contendo resultados de medições de tensão e corrente. Este banco de dados é constituído por medições em doze varistores de ZnO de cinco fabricantes diferentes, com diferentes dimensões físicas e características elétricas. Nos ensaios, os varistores foram submetidos a diversos níveis de tensão na região de baixas correntes. Também foram aplicados aos varistores vários níveis de amplitude de impulsos de corrente de manobra (30/60 µs), descarga atmosférica (8/20 µs), alta corrente (4/10 µs) e impulsos de corrente com frentes de onda mais rápidas (1,5/26 µs e 3/6 µs), abordando as regiões altamente não linear e altas correntes. Adicionalmente, outros ensaios foram realizados com objetivo de verificar a presença do acoplamento indutivo e a influência do invólucro do supressor de surto na medição da tensão residual. A partir do banco de dados, foram realizadas simulações com o MEP, e com os modelos Convencional e IEEE, já consolidados no meio científico. Os resultados dos modelos foram comparados entre si, e com os resultados de medição. O MEP apresentou melhores resultados em praticamente todos os casos, nas três regiões de operação. O MEP também foi avaliado em estudos reais de energização de linha de transmissão, rejeição de carga e coordenação de isolamento. Os resultados de simulação dos estudos apresentaram níveis de amplitude condizentes com o esperado, e não apresentaram oscilações numéricas ou instabilidade. Os parâmetros do MEP são de fácil determinação, e todas as informações necessárias estão contidas nos datasheets dos fabricantes. / This work proposes an electric model of ZnO surge arresters that represents accurately the ZnO surge arresters in a wide range of frequencies and amplitudes. The Proposed Electric Model (PEM) was validated from a database, containing results of voltage and current measurements. This database are based in twelve ZnO varistors of five different manufacturers, with different physical dimensions and electrical characteristics. In the lab tests, the varistors were submitted to different voltage levels in the low current region. There were also applied to the varistors multilevel amplitude of switching current impulses (30/60 µs), lightning current impulses (8/20 µs), high current impulses (4/10 µs) and current impulses with very fast front time (1.5/26 µs and 3/6 µs), addressing the highly nonlinear and high current regions. In addition, other lab tests were conducted in order to verify the presence of inductive coupling and the infuence of the surge arrester housing in the residual voltage measuring. From the database, simulations were performed with the PEM, with the Conventional and IEEE models which are already consolidated in the scientific community. The results of the models were compared among themselves, and with the measurement results. The PEM presented best results in practically all cases, in all three operating regions. The PEM was also evaluated in real studies of transmission line energization, load shedding and insulation coordination. The simulation results of the studies presented amplitude levels as expected and did not presented numerical oscillations or instability. The PEM parameters are easily determined, besides that all necessary information is contained in the manufacturers datasheet.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/897
Date06 June 2018
CreatorsBRITO, Valdemir da Silva.
ContributorsCOSTA, Edson Guedes da., LIRA, George Rossany Soares de., NEVES, Washington Luiz Araújo., FERNANDES JÚNIOR, Damásio., ALTAFIM, Ruy Alberto Correa., BEZERRA, José Maurício de Barros.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess
RelationCHESF

Page generated in 0.002 seconds