This paper describes a high fidelity simulation model for GEROTOR pumps. The simulation approach is based on the coupling of different models: a geometric model used to evaluate the instantaneous volumes and flow areas inside the unit, a lumped parameter fluid dynamic model for the evaluation of the displacing action inside the unit and mechanical models for the evaluation of the internal micro-motions of the rotors axes. This paper particularly details the geometrical approach, which takes into account the actual geometry of the rotors, given as input as CAD files. This model can take into account the actual location of the points of contact between the rotors as well for the actual clearances between the rotors. The potentials of the model are shown by considering a particular GEROTOR design. A specific test set-up was developed within this research for the model validation, and comparisons in terms of steady-state pressure versus flow curves and instantaneous pressure ripples are shown for the reference pump.
Identifer | oai:union.ndltd.org:DRESDEN/oai:qucosa.de:bsz:14-qucosa-199845 |
Date | 28 April 2016 |
Creators | Pellegri, Matteo, Vacca, Andrea, Devendran, Ram S., Dautry, Etienne, Ginsberg, Benjamin |
Contributors | Dresdner Verein zur Förderung der Fluidtechnik e. V.,, Technische Universität Dresden, Fakultät Maschinenwesen |
Publisher | Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden |
Source Sets | Hochschulschriftenserver (HSSS) der SLUB Dresden |
Language | English |
Detected Language | English |
Type | doc-type:conferenceObject |
Format | application/pdf |
Source | 10th International Fluid Power Conference (10. IFK) March 8 - 10, 2016, Vol. 1, pp. 465-476 |
Page generated in 0.0033 seconds