This research validates electro-disinfection as a potential secondary ballast water treatment technology. Electricity applied to bacteria laden water produced bactericidal effects, reactive oxygen species and chlorine generation which annihilated bacteria. Evaluation of electro-disinfection experiments showed titanium electrodes had the maximum kill efficacy while disinfection with aluminum and stainless steel electrodes had lesser kill efficacy. A continuous flow electro-disinfection reactor was evaluated utilizing artificial brackish and fresh ballast water. Brackish water had a 100% bacteria kill efficiency utilizing titanium electrodes at a current density of 10 mA/cm2. Fresh water was augmented with the addition of salt to increase its electrical conductivity from 232 μS/cm to 873 μS/cm to ascertain 100% bacteria kill efficiency with titanium electrodes and a current density of 9.8 mA/cm2.
Identifer | oai:union.ndltd.org:uno.edu/oai:scholarworks.uno.edu:td-2076 |
Date | 20 December 2009 |
Creators | McCraven, Elizabeth Kathleen |
Publisher | ScholarWorks@UNO |
Source Sets | University of New Orleans |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | University of New Orleans Theses and Dissertations |
Page generated in 0.0016 seconds