Cálculo de perdas técnicas e não técnicas nas redes de distribuição de energia elétrica usando a definição de impedância equivalente de perdas / Calculation of technical and non-technical losses in electricity distribution networks using the equivalent loss impedance definition

Submitted by Luciclea Silva (luci@ufpa.br) on 2018-11-01T14:00:58Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Calculoperdastecnicas.pdf: 10193002 bytes, checksum: 5e474814b95fa6c0f3457309da7a2950 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-11-01T14:01:22Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Calculoperdastecnicas.pdf: 10193002 bytes, checksum: 5e474814b95fa6c0f3457309da7a2950 (MD5) / Made available in DSpace on 2018-11-01T14:01:22Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Calculoperdastecnicas.pdf: 10193002 bytes, checksum: 5e474814b95fa6c0f3457309da7a2950 (MD5)
Previous issue date: 2018-10-17 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um novo conceito denominado Impedância Equivalente de Perdas (IEP) que é caracterizado por ser um método prático e econômico que permite calcular perdas técnicas e não técnicas em redes de distribuição de energia elétrica com uma boa
precisão, para o qual é utilizado dados que qualquer empresa de distribuição possui, como as contas de energia dos consumidores, os parâmetros elétricos da rede e as medições de potências
e correntes na saída da subestação. Para mostrar a aplicação deste método, este documento abrange o processamento dos dados e descrição do software usado para simular a operação de sistemas elétricos testes IEEE 13 e 37 barras, considerando que eles apresentam perdas técnicas e não técnicas. Além disso, estes sistemas são avaliados com diferentes condições de operação,
incluindo a incorporação de um gerador fotovoltaico. Os casos avaliados neste trabalho mostram que o método pode ser utilizado para planejar e monitorar as redes de distribuição de energia elétrica considerando a separação de perdas técnicas e não técnicas, para que no futuro as ações de redução dessas perdas possam ser gerenciadas, já que a perda de energia elétrica sem gerenciamento traduz-se em perdas econômicas consideráveis tanto para as
concessionárias quanto para os consumidores e indiretamente para o país. Os resultados apresentados nesta dissertação, sobre a aplicação da Impedância Equivalente de Perdas no cálculo das perdas técnicas e não técnicas demonstraram a eficácia do método proposto, vislumbrando-se um grande potencial para a aplicação desse procedimento nas empresas de energia elétrica, principalmente nas distribuidoras de energia. / This work presents a new concept called Loss Equivalent Impedance (LEI), which is characterized by being a practical and economical method that allows calculating technical and non-technical losses in electricity distribution networks with good accuracy, for which it uses
the data that any electric utility has, such as the user's electricity bills, the grid's electrical parameters and the measurements of power and currents at the substation coupling point. To show the application of this method, this document covers the data processing and description of the software used to simulate the operation in the test systems IEEE 13 and 37 buses networks, considering that they present technical and non-technical losses. In addition, these systems are evaluated with different operational conditions, including the incorporation of a photovoltaic plant. The cases evaluated in this work show that the method can be used to plan and monitor the electricity distribution networks, considering the separation of technical and non-technical losses, so that in future reduction actions concerning these losses can be managed, since of unmanaged electricity losses is translated into considerable economic losses for both the utility and customers and indirectly for the country. The results presented in this dissertation, regarding the application of the Equivalent Operational Impedance to the calculation of technical and non-technical losses, have demonstrated the effectiveness of the proposed methodology, so that it is foreseen a great potential for the application of the proposed procedure in the electrical sector mainly in the distribution utilities.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10347
Date17 October 2018
CreatorsPAYE, Juan Carlos Huaquisaca
ContributorsBEZERRA, Ubiratan Holanda
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Source1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA