Return to search

Comparison Of Performance Of Switched Reluctance Motors, Induction Motors And Permanent Magnet Dc Motors

Since most of the electrical energy is consumed by the electrical motors, it is necessary to use the electrical energy as efficient as possible.
Throughout this study four different types of motors (induction motor, permanent magnet radial flux DC motor, permanent magnet axial flux DC motor, switched reluctance motor) are considered and compared based on their torque per unit volume and speed performance comparison. Torque per unit volume equations are obtained for each of the motor, related to quantities such as magnetic flux density and electric loading and the speed performances are compared by using a washing machine application, which has a wide speed range.
As a result of this study torque per unit volume and speed performance of each of these four types of motors are obtained and motors of different types are evaluated due to their torque per motor volume, torque per ampere, efficiency and etc. over a wide speed range to have an idea about the applications of these motors.

Identiferoai:union.ndltd.org:METU/oai:etd.lib.metu.edu.tr:http://etd.lib.metu.edu.tr/upload/12604925/index.pdf
Date01 May 2004
CreatorsKaracan, Cuneyt
ContributorsUctug, Yildirim
PublisherMETU
Source SetsMiddle East Technical Univ.
LanguageEnglish
Detected LanguageEnglish
TypeM.S. Thesis
Formattext/pdf
RightsTo liberate the content for public access