Design of a Radial Mode Piezoelectric Transformer for a Charge Pump Electronic Ballast with High Power Factor and Zero Voltage Switching

In a conventional electronic ballast for a fluorescent lamp, inductor-capacitor-transformer tank circuit is used. A Piezoelectric Transformer (PT) can potentially be used to replace such a tank circuit to save space and cost. In the past, ballast design using a PT requires selecting a PT from available samples which are normally not matched to specific application and therefore resulting in poor performance. In this thesis, a design procedure was proposed for designing a PT tailored for a 120-V 32-W electronic ballast with high power factor, high efficiency and Zero-Voltage-Switching (ZVS) of the inverter transistors that drive the lamp. This involves selection of PT materials, determination of geometries and the number of physical layers of the PT. A radial mode piezoelectric transformer prototype based on this design process was fabricated by Face Electronics Inc. and was tested experimentally, the results showed that the ballast using this custom-made PT achieved high power factor, Zero-Voltage-Switching and a 83% overall efficiency. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/31818
Date01 May 2003
CreatorsHuang, Weixing
ContributorsElectrical and Computer Engineering, Chen, Dan Y., Huang, Alex Q., Lindner, Douglas K.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
Detected LanguageEnglish
TypeThesis
Formatapplication/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationwhuangthesisFinal.pdf

Page generated in 0.0018 seconds