Submitted by Patrícia Cerveira (pcerveira1@gmail.com) on 2017-06-12T18:19:03Z
No. of bitstreams: 1
José Renato Cozzolino.pdf: 2923143 bytes, checksum: 2941736082bf50938fdb3dcfea03c36e (MD5) / Approved for entry into archive by Biblioteca da Escola de Engenharia (bee@ndc.uff.br) on 2017-07-03T13:30:54Z (GMT) No. of bitstreams: 1
José Renato Cozzolino.pdf: 2923143 bytes, checksum: 2941736082bf50938fdb3dcfea03c36e (MD5) / Made available in DSpace on 2017-07-03T13:30:54Z (GMT). No. of bitstreams: 1
José Renato Cozzolino.pdf: 2923143 bytes, checksum: 2941736082bf50938fdb3dcfea03c36e (MD5) / A estimação correta de frequência é essencial para a operação de diversos equipamentos de proteção, regulação e controle, os quais são necessários para operação adequada do Sistema Interligado Nacional A tecnologia de Sistemas de Medição Fasorial Sincronizada (Synchronized Phasor Measurement Systems - SPMS), baseia-se em uma rede de Unidades de Medição Fasorial (Phase Measurement Unit - PMU). Duas grandezas importantes medidas pela PMUs são a frequência e a taxa de variação da frequência. Este trabalho apresenta o resultado de estudo comparativo de algoritmos de estimação de frequência no âmbito de medição fasorial sincronizada. Foram avaliados os modelos propostos originalmente pela Norma IEEE C37.118, por seu documento de alteração ( IEEE Std. C37.118.1a-2014 Amendment), alem de três diferentes tipos de algoritmos baseados em PLLs (Phasor Locked Loop). As avaliações foram executadas com base nos testes descritos na Norma IEEE C37.118 e seus respectivos requisitos de conformidade. Verificou-se que as modificações apresentadas pelo documento Amendment foram necessárias para que o modelo de PMU proposto atendesse os requisto para todos os testes. Em relação aos modelos de PLL, verificou-se que uma versão do algoritmo (chamada aqui de PLL de Classe III) foi bem superior às demais e também melhor que o algoritmo sugerido pelo Amendment no que se refere ao teste de derivada da frequência e de modulação de fase. / An accurate frequency estimation is essential for the operation of Electric Power System regarding protection and control. Synchronized Phasor Measurement Systems - SPMS are based on a network composed by Phasor Measurement Units (Phase Measurement Unit - PMU). Two important parameters measured by the PMUs are the frequency and the frequency rate of change. This paper presents the results of a comparative study of frequency estimation algorithms within synchronized phasor measurement context. The reference model proposed in by IEEE C37.118 standard was compared with three different algorithms based on PLLs (Phasor Locked Loop). The evaluations were performed based on the compliance requirements described in IEEE C37.118. It was also found that the PLLs models have superior performance than model reference for P PMU suggested by Standard. Regarding the reference model for PMU M, there is a need to implement anti-aliasing filters for the standard inter-harmonics tests. After that, it was observed that the dynamic performances of PLLs studied at work are compatible with the algorithms suggested by the standard for the PMU M.
Identifer | oai:union.ndltd.org:IBICT/oai:https://app.uff.br/riuff:1/3936 |
Date | 03 July 2017 |
Creators | Souza, José Renato Cozzolino Rodrigues de |
Contributors | Carvalho, Murilo Bresciani de, Taranto, Glauco Nery, Alves Junior, José Eduardo da Rocha, Larrea, José Andrés Santisteban |
Publisher | Niterói |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFF, instname:Universidade Federal Fluminense, instacron:UFF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0017 seconds