Return to search

Influência de primers dentinários modificados por digluconato de clorexidina na resistência de união de pinos de fibra de vidro em dentina radicular /

Orientador: Paula Carolina Komori de Carvalho / Coorientador: Ronaldo Luís Almeida de Carvalho / Banca: Fernanda de Cássia Papaiz Gonçalves / Banca: Estevão Tomomitsu Kimpara / Resumo: O estudo avaliou in vitro o efeito da modificação de primers dentinários com digluconato de clorexidina na resistência de união de pinos de fibra de vidro em dentina radicular. A hipótese testada considerou que a incorporação de clorexidina em primers dentinários não interferiria na resistência de união de pinos de fibra de vidro independentemente da profundidade da dentina radicular testada imediatamente e após envelhecimento. Sessenta raízes retilíneas bovinas foram selecionadas e divididas aleatoriamente em 6 grupos (n=10). As raízes foram obturadas e os condutos preparados de modo sequencial e padronizado para receber os pinos de fibra de vidro que foram silanizados previamente. A dentina radicular foi condicionada com ácido fosfórico 37% por 15s, seguido da aplicação do primer do sistema adesivo convencional ou primer modificado, seguido da aplicação do adesivo dentinário. Os primers experimentais foram preparados, incorporando solução aquosa ou alcóolica de clorexidina com concentração de 0,12%. O cimento resinoso dual foi inserido no interior das raízes e os pinos posicionados para fotoativação durante 40s. Para determinar a resistência de união, metade das amostras foram cortadas transversalmente em 3 secções em diferentes profundidades da dentina radicular, e testadas imediatamente por push-out, em uma máquina de ensaios universal (EMIC), com célula de carga de 100Kgf e velocidade de 1mm/min. A outra metade das amostras receberam reconstrução coronária com resina com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present in vitro study evaluated the influence of modified dentin primers containing chlorhexidine digluconate on bond strength of glass fiber posts to radicular dentin. The hypothesis to be tested considers that the incorporation of chlorexidine in dentin primers does not interfere on the bond strength of glass fiber posts independently of the analyzed radicular dentin depth tested immediately or after thermocycling aging. Sixty rectilinear bovine roots were selected and randomly distributed into 6 groups (n=10). The endodontically treated root canals were sequentially and standardized prepared for glass-fiber posts insertion, which were previously silanized. The radicular dentin was etched with 37% phosphoric acid for 15s and conditioned using the conventional primer or the modified primer followed by the corresponding adhesive. Experimental primers were prepared by adding aqueous or alcoholic solutions of chlorexidine to obtain a 0.12% concentration. A dual- cured resin cement was inserted into the root canals and the posts were positioned for light polymerization for 40s.To measure the bond strength, half of the samples were transversally sectioned into 3 slices from different radicular regions, and immediately processed for push-out test into an universal test machine (EMIC), with a load-cell of 100Kgf, and at a speed of 1mm/min. The other half a coronary reconstruction was conducted with composite resin, based on a standardized silicon matrix. The periodontal ligame... (Complete abstract click electronic access below) / Mestre

Identiferoai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000908637
Date January 2018
CreatorsCanineo, Simone Yumi Sudo.
ContributorsUniversidade Estadual Paulista "Julio de Mesquita Filho" Instituto de Ciência e Tecnologia (Campus de São José dos Campos).
PublisherSão José dos Campos,
Source SetsUniversidade Estadual Paulista
LanguagePortuguese, Portuguese, Texto em português; resumos em português e inglês
Detected LanguagePortuguese
Typetext
Format46 f.
RelationSistema requerido: Adobe Acrobat Reader

Page generated in 0.002 seconds