O objetivo do estudo foi medir a acuidade visual (AV) em crianças com diagnóstico de hidrocefalia, apresentando ou não a válvula de derivação ventricular (DVP). Participaram da pesquisa um total de 55 crianças (34 F e 21M) com diagnóstico de hidrocefalia (45 com DVP e 10 sem DVP), com idade entre zero a 291 semanas (média 74 semanas). A AV foi medida pela técnica do Potencial Visual Evocado de Varredura e os resultados foram comparados a valores de referência (Norcia, 1985b). Os diagnósticos etiológicos que levaram à hidrocefalia foram: hemorragia intracraniana (25 crianças), mielomeningocele (20 crianças) e hidrocefalia congênita (10 crianças). O diagnóstico de hidrocefalia foi estabelecido em média no 16° dia de vida. Verificamos que, 31 crianças tiveram o procedimento realizado com menos de 15 dias do diagnóstico de hidrocefalia enquanto que em 14 a válvula foi instalada após 15 dias. Das 55 crianças avaliadas no 1° exame, 18 fizeram o 2° exame, 13 fizeram o 3° exame, 10 completaram quatro exames e apenas cinco completaram as cinco avaliações. Os resultados mostram que dentre as 101 avaliações de AV realizadas em todas as crianças, 95 exames (94%) se mostraram alterados e seis normais. Não há diferença estatística entre a AV das crianças sem derivação em comparação com aquelas crianças cuja DVP foi realizada com tempo de derivação maior que 15 dias (p = 0.699). Houve, todavia, uma diferença estatística na AV, quando comparamos as crianças, cujas derivações foram realizadas em até 15 dias do diagnóstico da hidrocefalia, com aquelas cuja derivação foi realizada após 15 dias (p = 0.038) ou com aquelas que não foram derivadas (p = 0.031). Crianças que não tiveram complicações na DVP tiveram um melhor resultado de AV quando comparado com o grupo com complicação (p = 0.0001). No grupo de crianças com complicação, novamente aquelas que foram derivadas com tempo inferior a 15 dias do diagnóstico da hidrocefalia apresentou melhores resultados de AV quando comparado com aquelas crianças com complicação cuja derivação foi realizada com mais de 15 dias (p = 0.029). Nós concluímos que é possível a medida da acuidade visual de resolução pelos PVEs de varredura em crianças com diagnóstico de hidrocefalia e os valores geralmente são piores comparando aos valores normativos. O tempo da derivação e o número de complicações decorrentes da DVP parecem interferir nesta diferença. Em nosso conhecimento, este foi o primeiro trabalho a avaliar progressivamente, a acuidade visual de crianças, nos primeiros anos de vida, com hidrocefalia, com ou sem DVP e correlacionar o resultado com o tempo de derivações e número de complicações. Apesar da grande evolução tecnológica alcançada pela oftalmologia, ainda não somos capazes de prevenir as alterações visuais detectáveis pelo simples exame de AV nas crianças com hidrocefalia. O tempo para a inserção da válvula de derivação e o tratamento para as complicações ainda são medidas retardadas devido à prematuridade, instabilidade hemodinâmica e a não autorização do familiar. Estes motivos podem comprometer o desenvolvimento visual destas crianças. / The objective was to measure the visual acuity (VA) of children with the diagnosis of hydrocephalus with or without peritoneal-ventricular shunt (PVS). A total of 55 children with the diagnosis of hydrocephalus (45 with PVS and 10 without PVS) were included in the study (34F and 21M), with an age range of 0 to 291 weeks (mean=74 weeks). The VA was measured by the sweep visual evoked potential technique and the results were compared with reference values proposed by Norcia (1985b). Etiological diagnosis of the hydrocephalus was as follows: intracranial hemorrhage (25 children), meningomyelocele (20 children) and congenital hydrocephalus (10 children). The diagnosis of hydrocephalus was made in an average time of 16 days of life. After the diagnosis, the insertion of the PVS, when made, was accomplished in average on the 16th day. Of those with a PVS, in 31 the ventricular valve was inserted before 15 days after the diagnosis whereas in 14 in shunt was inserted after 15 days. Of the 55 children evaluated in the first exam, 18 were evaluated in a second exam, 13 did the third exam, 10 completed 4 exams and only 5 completed the 5 evaluations. The results of the 101 sweep visual evoked potential performed in all children, 95 exams (94%) were abnormal and only 6 were normal. There was no statistical difference in the VA of children without a ventricular shunt in comparison with those in which the shunt was inserted after 15 days of the diagnosis of hydrocephalus (p=0.699). There was, however, a statistical difference in the VA between children with a ventricular shunt inserted before 15 days of the diagnosis and children with a ventricular shunt after 15 days (p=0.038) or those without a shunt (p=0.031). Children with no complications of the ventricular shunt had a better VA as compared to those with shunt complications (p= 0.0001). In the group of children with complications, again those who had a shunt inserted before 15 days bad better VA results in comparison to those in whom the shunt was inserted after 15days (p=0.029). We concluded that measuring visual acuity by sweep visual evoked potential is feasible in children with the diagnosis of hydrocephalus and that results are usually worse comparing with reference values. The timing for insertion of a ventricular shunt and the occurrence of complications of this procedure are factors that may influence the VA. To our knowledge, this is the first study that progressively evaluated the VA in children, of early age, with hydrocephalus, with or without a ventricular shunt and correlated the VA with the timing and complications of the ventricular shunt. Despite the great technological advance in ophthalmology, we are still unable to prevent visual impairments, detectable by simple visual acuity tests, in children with hydrocephalus. The timing of the insertion of the ventricular shunt and the adequate treatment of the potential complications may be delayed due to prematurity, hemodynamic instability and family refusal. This delay may compromise the visual development of these children.
Identifer | oai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-10062008-105554 |
Date | 22 April 2008 |
Creators | Silvana Alves Pereira |
Contributors | Marcelo Fernandes da Costa, Nielsy Helena Puglia Bergamasco, Albert Bousso |
Publisher | Universidade de São Paulo, Neurociências e Comportamento, USP, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds