No / Tank flooding have become major causes of pollution both in residential and industrial areas majorly caused by overflows of water(mostly residential) and volatile poisonous industrial liquids from the storage tanks. An effective way of avoiding this problem will be by deploying some mechanism to monitor liquid level at each point in time and escalating unusual liquid levelsto a pump control circuit or to the relevant authorities for prompt action to avoid a flooding occurrence. This paper presents a low cost power efficient liquid level monitoring technique. Passive RFID tags are designed modelled and deployed, the signal variation from the Alien Reader Software are used to effectively estimate the level of liquid in any surface or underground tank. The experimental set up is presented and an expository presentation is made of the passive tag design, modelled and simulated and adopted for same application.
Identifer | oai:union.ndltd.org:BRADFORD/oai:bradscholars.brad.ac.uk:10454/9620 |
Date | January 2013 |
Creators | Atojoko, Achimugu A., Bin-Melha, Mohammed S., Elkhazmi, Elmahdi A., Usman, Muhammad, Abd-Alhameed, Raed, See, Chan H. |
Source Sets | Bradford Scholars |
Language | English |
Detected Language | English |
Type | Conference paper, No full-text in the repository |