This thesis deals with the cartilage imaging using magnetic resonance. At first, there is mentioned physical principle of the magnetic resonance phenomenon and the most commonly used excitation sequences, followed by the description of the 9.4 T MR imaging system Bruker BioSpec 94/30 USR, which was used for measurement in the practical part. The next part is dedicated to the composition of cartilages and describes the temporomandibular joint, due to its suitability as an object for cartilage imaging. The series of MR scans of temporomandibular joint were taken with different acquisition parameters and evaluated by program designed through the MATLAB software. The program can be used for viewing scanned images, evaluating their contrast and determining the T1 relaxation time of the tissues by creating T1 maps.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:316833 |
Date | January 2017 |
Creators | Němcová, Simona |
Contributors | Jiřík, Radovan, Krátká, Lucie |
Publisher | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0018 seconds