Return to search

Evaluation of the wearable blood pressure measurement devices.

Xiang Xiaoyan. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2006. / Includes bibliographical references. / Abstracts in English and Chinese. / Chapter Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Background of Hypertension --- p.1 / Chapter 1.1.1 --- Definition of Blood Pressure --- p.1 / Chapter 1.1.2 --- Hypertension and Its Prevalence --- p.2 / Chapter 1.2 --- Blood Pressure Measurement Techniques --- p.5 / Chapter 1.2.1 --- Invasive Blood Pressure Measurement Techniques --- p.5 / Chapter 1.2.2 --- Non-invasive Blood Pressure Measurement Techniques --- p.6 / Chapter 1.3 --- Accurate BP Measurements --- p.12 / Chapter 1.3.1 --- Error Source for BP Measurement by Conventional Techniques --- p.12 / Chapter 1.3.2 --- Accurate BP Measurement --- p.13 / Chapter 1.4 --- Objectives of the Thesis --- p.15 / Chapter 1.5 --- Organization of the Thesis --- p.16 / References --- p.17 / Chapter Chapter 2 --- Current Standards for the Conventional Blood Pressure Measurement Devices --- p.20 / Chapter 2.1 --- Introduction --- p.20 / Chapter 2.2 --- Current Standards for the Cuff-based BP Measurement Devices --- p.21 / Chapter 2.2.1 --- AAMI Standard --- p.21 / Chapter 2.2.2 --- BHS Protocol --- p.22 / Chapter 2.2.3 --- Other Protocols --- p.23 / Chapter 2.3 --- Comparison of the 2002 AAMI and 1993 BHS Protocols - Protocol Setup --- p.25 / Chapter 2.4 --- Comparison of the 2002 AAMI and 1993 BHS Protocols 一 Accuracy Criteria --- p.29 / Chapter 2.5 --- Relationship between the AAMI Accuracy Criteria and the BHS Grading System --- p.31 / Chapter 2.5.1 --- Theoretical Mapping Relationship --- p.31 / Chapter 2.5.2 --- Application of the Mapping Model: Estimate the BHS Grades from the Reported Sample ME and SD --- p.34 / Chapter 2.5.3 --- Application of the Mapping Model: Explain the Evaluation of the Results from the Clinical Survey by the ESH --- p.36 / Chapter 2.6 --- Discussion --- p.36 / References --- p.40 / Chapter Chapter 3 --- Distribution Analysis of the Blood Pressure Measurement Errors --- p.42 / Chapter 3.1 --- Introduction --- p.42 / Chapter 3.2 --- Error Distribution Estimated from the Published Data --- p.43 / Chapter 3.2.1 --- Methodology --- p.43 / Chapter 3.2.2 --- Data Analysis --- p.44 / Chapter 3.2.3 --- Session Summary --- p.46 / Chapter 3.3 --- Error Distribution Estimated from the Experimental Data --- p.46 / Chapter 3.3.1 --- BP Measurement Error Obtained from Automatic BP Meter --- p.46 / Chapter 3.3.2 --- Distribution Analysis by the Normal Quantile-Quantile Plot --- p.47 / Chapter 3.3.3 --- Background of Student's t Distribution --- p.48 / Chapter 3.3.4 --- Parameter Estimation - Maximum Likelihood Method --- p.50 / Chapter 3.3.5 --- Goodness-of-fit Test - Kolmogorov-Smirnov Test --- p.53 / Chapter 3.3.6 --- Goodness-of-fit Test ´ؤ Chi-Square Test --- p.56 / Chapter 3.4 --- Discussion --- p.63 / References --- p.65 / Chapter Chapter 4 --- A Model Based Study of the Parameters Used by Existing Standards --- p.67 / Chapter 4.1 --- Introduction --- p.67 / Chapter 4.2 --- Background of Method Comparison Study --- p.68 / Chapter 4.2.1 --- Four Areas in Method Comparison Study --- p.68 / Chapter 4.2.2 --- Analysis of Previous Methodology and Statistical Parameters --- p.70 / Chapter 4.3 --- Theoretical Mapping Relationship: Based on the General t Distribution --- p.72 / Chapter 4.3.1 --- "Relationship among CP5, CP10 and CP15 in Each Grade for the 1993 BHS Protocol" --- p.76 / Chapter 4.3.2 --- Relationships between the Criteria in Each Grade for the 1993 BHS Protocol and the AAMI Standard --- p.77 / Chapter 4.3.3 --- Comparison of Parameters --- p.80 / Chapter 4.4 --- Mean of the Absolute Errors (MAE) and Its Estimation --- p.81 / Chapter 4.4.1 --- The Relationship between MAE and Other Parameters --- p.81 / Chapter 4.4.2 --- Analysis of the Example Data --- p.84 / Chapter 4.4.3 --- Estimation of MAEt --- p.84 / Chapter 4.5 --- Discussion --- p.88 / References --- p.90 / Chapter Chapter 5 --- Experimental Study and an Evaluation Protocol Proposed for the Wearable BP Measurement Devices --- p.92 / Chapter 5.1 --- Introduction --- p.92 / Chapter 5.2 --- Description of the Experiment --- p.93 / Chapter 5.3 --- Data Analysis --- p.95 / Chapter 5.3.1 --- Data Used for the Study --- p.95 / Chapter 5.3.2 --- Error Distribution Analysis --- p.96 / Chapter 5.3.3 --- Evaluation of the Automatic BP Meter and the PTT-Based BP Measurement Device by AAMI and 1993 BHS Standards --- p.99 / Chapter 5.3.4 --- Evaluation the Automatic BP Meter and the PTT-Based BP Measurement Device by the Proposed Parameter --- p.101 / Chapter 5.4 --- Proposed Evaluation Procedure --- p.101 / Chapter 5.4.1 --- Introduction --- p.101 / Chapter 5.4.2 --- Determination of Parameters and Criteria --- p.102 / Chapter 5.4.3 --- Proposed Evaluation Procedure --- p.103 / Chapter 5.5 --- Discussion --- p.105 / References --- p.108 / Chapter Chapter 6 --- Conclusion and Future Work --- p.110 / Chapter 6.1 --- Conclusion and Major Contributions --- p.110 / Chapter 6.2 --- Future Works --- p.113 / References --- p.115 / Appendix A Deviation of Some Equations --- p.116 / Chapter A.1 --- CP for Certain Limit of L as a Function of ME and SD --- p.116 / Chapter A.2 --- MAE as a Function of Location and Scale Parameters --- p.119 / Chapter A.3 --- "Relationship between ME, MAE and Root Mean Squared Error (RMSE) if the error distribution is unknown" --- p.121 / Appendix B List of Publications and Awards Related to This Study --- p.123

Identiferoai:union.ndltd.org:cuhk.edu.hk/oai:cuhk-dr:cuhk_325879
Date January 2006
ContributorsXiang, Xiaoyan., Chinese University of Hong Kong Graduate School. Division of Electronic Engineering.
Source SetsThe Chinese University of Hong Kong
LanguageEnglish, Chinese
Detected LanguageEnglish
TypeText, bibliography
Formatprint, xiv, 123 leaves : ill. ; 30 cm.
RightsUse of this resource is governed by the terms and conditions of the Creative Commons “Attribution-NonCommercial-NoDerivatives 4.0 International” License (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Page generated in 0.0019 seconds