Return to search

Estudo da transferência de calor e queda de pressão na ebulição do r-600a em mini canais paralelos

Submitted by Maicon Juliano Schmidt (maicons) on 2015-05-25T14:45:18Z
No. of bitstreams: 1
Bruno de Sá Beckerle.pdf: 3991624 bytes, checksum: 500b993c0f3a1c3a8c3abae05ed51c5e (MD5) / Made available in DSpace on 2015-05-25T14:45:18Z (GMT). No. of bitstreams: 1
Bruno de Sá Beckerle.pdf: 3991624 bytes, checksum: 500b993c0f3a1c3a8c3abae05ed51c5e (MD5)
Previous issue date: 2015-01-05 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo experimental da transferência de calor e queda de pressão na ebulição do isobutano, R-600a, em um tubo composto por 7 mini canais paralelos, cujo diâmetro hidráulico é de 1,47 mm. Os testes em ebulição foram realizados com uma temperatura de saturação de 22 ºC e pressão de saturação de 302 kPa, com velocidade mássica entre 50 e 200 kg/(m²s) e fluxos de calor na seção de testes entre 7 e 40 kW/m². Com os testes realizados verificou-se que o coeficiente de transferência de calor aumenta conforme o incremento do fluxo de calor e velocidade mássica, sendo que esta última tem maior influência para baixos títulos de vapor. O coeficiente de transferência de calor atingiu valores máximos próximos a 3.200 W/(m²K) para a condição de maior vazão e fluxo de calor. A queda de pressão aumentou com o incremento da velocidade mássica e título de vapor em todos os testes, enquanto que o fluxo de calor apresentou influência na queda de pressão apenas nas maiores velocidades mássicas. A perda de pressão por atrito representou até 93,7% da perda total. Também foram analisados os padrões de escoamento, sendo observados os padrões de bolhas isoladas, bolhas alongadas, intermitente e anular, sendo que o padrão de bolhas isoladas foi observado para baixos fluxos e títulos de vapor, e o padrão anular mostrou-se presente para títulos superiores a 0,13. / This work presents an experimental study of heat transfer and drop pressure in flow boiling of the isobutane, R-600a, in a 7 mini channel of 1,47 mm hydraulic diameter. The tests were performed a boiling with a saturation temperature of 22 °C and saturation pressure of 302 kPa, with a mass velocity between 50 and 200 kg/(m²s) and heat fluxes in the test section between 7 and 40 kW/m². In the tests, it was found that the heat transfer coefficient increases with increasing heat flux and mass velocity has more influence at low quality. The heat transfer coefficient achieved values around 3.200 W/(m²K) for the condition of greater flow and heat flux. The drop pressure was increase by increasing the mass velocity and quality in all tests, while the heat flow have any influence on the drop pressure to the greater mass velocity. The friction drop pressure represented to 93.7% of the total loss. As well analyzed the flow patterns, and observing the patterns of isolated bubbles, plugs/slugs, intermittent and annular, and that the pattern of isolated bubbles were observed for low quality and heat flux and the annular pattern was present for quality from 0.13.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/3644
Date05 January 2015
CreatorsBeckerle, Bruno de Sá
Contributorshttp://lattes.cnpq.br/9219989574784501, Copetti, Jacqueline Biancon
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds