Orientador : Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T16:58:21Z (GMT). No. of bitstreams: 1
Oliveira_AnaEmiliaFigueiredode_D.pdf: 10687207 bytes, checksum: 87989b4029d419522329601c38b34367 (MD5)
Previous issue date: 2001 / Resumo: O objetivo no presente trabalho foi a realização de uma análise conjunta, subjetiva e objetiva, da qualidade de imagem de quatro sistemas radiográficos digitais intrabucais, visando correlacionar seus resultados. Empregou-se dois sistemas de armazenamento de fósforo, Digora e DenOptix, e dois sistemas CCD, CDR e Sens-A-Ray. Na análise clínica, utilizou-se como objetos de estudo quatro regiões anatômicas dentais e uma escala de densidade de alumínio, que foram avaliadas por seis radiologistas, num total de 280 imagens. A análise objetiva foi realizada por meio de um Sistema Integrado, composto de phantoms específicos e um pacote computacional, que propiciaram a estimativa automática dos parâmetros físicos em 2050 imagens. Os resultados permitiram. que se concluísse que, em ambas análises, os sistemas de armazenamento de fósforo se apresentaram, de uma forma geral, com um melhor desempenho que os sistemas CCD. O Digora apresentou-se como o sistema de melhor performance física, e o Sens-A-Ray como o sistema de mais baixo desempenho. Existiu uma forte relação entre os resultados de ambas análises, excetuando-se os referentes à resolução espacial e ao MTF, onde se pôde concluir, que o "padrão ouro" para relacionar com eficiência os parâmetros físicos e a qualidade de diagnóstico dos sistemas radiográficos digitais é a análise conjunta do DQE, do SNR e do contraste da imagem / Abstract: The objective of the present work was the accomplishment of a subjective and objective analysis of the image quality of four digital intra-oral radiographic systems, aiming at to correlate its results. It was used two storage phosphor systems, Digora and DenOptix, and two CCD systems, CDR and Sens-A-Ray. In the clinical analysis, it was used as study object four dental anatomical regions and an aluminum stepwedge, that had been analyzed by six radiologist, in a total of 280 images. The objective analysis was carried through by means of an Integrated System, composed by specific phantoms and a computational package that got possible the automatic estimate of the physical parameters in more than 2000 images. The results had shown that, in both analyses, the storage phosphor systems had presented, of a general form, a better performance than CCD systems. The Digora system presented the best physical performance, with the Sens-A-Ray behaving with the lowest results. There was a strong relation between the results of both analyses, excepting itself referring the space resolution and to the MTF, where it could be concluded that the "gold pattern" to relate with efficiency the physical parameters and the capacity of diagnosis of the digital radiographic systems is the joint analysis of the DQE, the SNR and the contrast of the image / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288909 |
Date | 17 July 2001 |
Creators | Oliveira, Ana Emilia Figueiredo de |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Boscolo, Frab Norberto, 1942-, Moraes, Luis Cesar de, Costa, Claudio, Pereira, Antonio Carlos, Haiter Neto, Francisco |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 273p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds