Return to search

Gerenciamento de demanda de água em ambientes de uso público: o caso da Universidade Federal de Campina Grande. / Management of water demand in public buildings: the case of the Universidade Federal de Campina Grande.

Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-09-27T15:24:05Z
No. of bitstreams: 1
ANTONIO LEOMAR FERREIRA SOARES - DISSERTAÇÃO PPGECA 2012..pdf: 13208663 bytes, checksum: b3c6e6dddf91e5d0adb7fe7815cd422b (MD5) / Made available in DSpace on 2018-09-27T15:24:05Z (GMT). No. of bitstreams: 1
ANTONIO LEOMAR FERREIRA SOARES - DISSERTAÇÃO PPGECA 2012..pdf: 13208663 bytes, checksum: b3c6e6dddf91e5d0adb7fe7815cd422b (MD5)
Previous issue date: 2012-02 / A água, um bem indispensável à vida, está se tornando a cada dia mais escasso,
principalmente nas regiões semiáridas, como o Nordeste brasileiro, caracterizadas por secas sucessivas. Uma forma de solução sustentável é a gestão da demanda de água (GDA) - baseada no uso eficiente, garantindo a água no futuro, a partir do uso consciente no presente. Neste contexto, esta pesquisa partiu desses conceitos para estudar o caso da Universidade Federal de Campina Grande (UFCG), por ser um ambiente público, grande consumidor e sujeito a grandes desperdícios de água. Na análise foram diagnosticados o local e o sistema de abastecimento interno, o comportamento e percepção dos usuários para práticas de uso eficiente da água através de entrevistas e, por fim, simulações de medidas de GDA. Constatou-se através dos dados levantados que a demanda de água da UFCG apresentou crescimento absoluto de 118% de 2004
até 2010, ocasionado seja pelo crescimento da população, da área construída, dos vazamentos do sistema de abastecimento e maus hábitos dos usuários. Em relação aos usuários percebeu-se reprovação com seus hábitos de conservação de água, pois 75% afirmaram desperdiçar muita água na utilização dos aparelhos, sendo atribuída por eles próprios (76%) nota abaixo de 6,0 para suas condutas. Esta mesma avaliação sobre os usuários repercutiu na visão dos gestores da Instituição, que ainda consideraram importante a implantação de programas de redução de água devido às suspeitas de muita perda de água por vazamentos. Com as simulações verificaram-se índices de redução de consumo de água de até 50% com a substituição das bacias sanitárias pelo sistema bi-comando (3/6 litros) e um retorno do investimento em menos de 12 meses. Quando
considerada a construção de cisternas para captação da água de chuva e aproveitamento no abastecimento das bacias sanitárias, verificou-se que para edificações com 8, 6 e 4 bacias sanitárias, a capacidade ótima do reservatório é de 20 m3, 25 m3 e 40 m3, com um índice de aproveitamento do sistema em 11%, 18% e 32%, respectivamente, demonstrando serem as medidas viáveis tanto ambientalmente quanto financeiramente. / Water, which is essential for sustaining life, is increasingly scarce, especially in semiarid
regions such as northeastern Brazil, characterized by successive droughts. The management of water demand (MWD) is a sustainable solution - based on efficiency, ensuring water availability in the future, through the conscious use in the present. In this context, this research was based on these concepts in order to promote a reduction in water consumption. The case of the Universidade Federal de Campina Grande (UFCG) was studied, since it is a public setting, a large consumer of water and subjected to large water losses. In the analysis, the site and the supply system of UFCG were diagnosed, as well as the behavior and perception of users related to efficient water use, through interviews, and, finally, simulations of strategies of MWD were performed. It was found that the water demand at UFCG presented an absolute growth of 118% from 2004 to 2010, which was caused by growth of population, construction area, supply system leaks and bad habits of users. Regarding users, it was perceived disapproval of their own water
conservation habits. This same assessment about users is shared by the managers of the
institution, who considered to implement programs of water use reduction. The simulations
showed reduced rates of water consumption up to 50% with the replacement of toilets at bicommand (3/6 liters) flush and a return of investment in less than 12 months. When considering construction of cisterns to capture rainwater and use in the supply of toilets, it was found that for buildings with 8, 6 and 4 toilets, the optimum capacity of the reservoirs are 20 m\ 25 m3 and 40 m3 with a utilization rate of the system in 11%, 18% and 32%, respectively, showing that the strategies are both environmentally and fmancially viable.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/1833
Date27 September 2018
CreatorsSOARES, Antonio Leomar Ferreira.
ContributorsGALVÃO, Carlos de Oliveira., MORAIS, Marcele Trigueiro de Araújo., LUCENA, Flávio Meira de., MIRANDA, Lívia Izabel Bezerra de., BONATES, Eduardo Jorge Lira.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL, UFCG, Brasil, Centro de Tecnologia e Recursos Naturais - CTRN
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds