Previous issue date: 1996 / Resumo: Desde que foi constatada a destruição do ozônio estratosférico, devido às reações com moléculas cloradas, muitos estudos têm sido desenvolvidos para se identificar substâncias alternativas aos CFCs. Misturas de hidrocarbonetos (propan.olisobutano) são apontadas como substâncias alternativas por serem refrigerantes naturais. Este trabalho trata da avaliação experimental do comportamento de um equipamento frigorífico de pequeno porte projetado para trabalhar com R12, operando com misturas de propano/isobutano (R260/R600a) nas concentrações molares de 60/40,46/54 e 20/80 sem nenhuma modificação no
sistema ou no óleo lubrificante. A temperatura de condensação esteve entre 33°C e 47°C para simular as condições climáticas de uma região tropical. Os parâmetros avaliados para cada fluido refrigerante foram: Coeficiente de Performance (COP), pressões, relação de pressão, temperaturas de descarga, condensação, evaporação e temperatura interna do gabinete bem como a influência do superaquecimento na sucção do compressor. O comportamento volumétrico das misturas de propanolisobutano é avaliado através da Equação de Estado de Peng-Robinson. Os resultados comparados com os da literatura demonstram, que apesar da inflamabilidade, a mistura de propano/isobutano com 60% de propano (R290) e 40% de isobutano (R600a) é adequada para substituir o R12 em ciclos frigoríficos de pequeno porte / Abstract: Since the stratrosphere ozone depletion has been observed many studies have been developed to find substances to replace chlorine compounds of chlorofluorocarbons. Hydrocarbon mixtures (propanelisobutane) were indicated because they are natural refrigerants. This work presents the experimental avaliation of a small freezer's behaviour working with R12 and with
propane/isobutane mixtures (R260/R600a) in molar concentration of 60/40, 46/54 and 20/80, without any change in the system or in the lubrification oil. The condensation temperatures were between 33°C and 47°C to simulate tropical ambiental conditions. The parameters tested with each refrigerant fluid were: evaporation and condensation pressures, evaporation condensation, discharge,
suction and cabinet temperatures and the influence of superheating of suction line. The volumetric behaviour of the mixtures of propane/isobutane was calculated by the Peng-Robinson equation of state. Inspite of high inflamability, comparision between these results and literature data shows that the propane/isobutane mixture with 60% of propane (R290) and 40% of isobutane (R600a) is adequate to substitute the R12 in freezers / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/262931
Date20 December 1996
CreatorsSantos, Genivaldo Pimenta dos
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Halasz, Judit Zoltan, 1942-, Halasz, Judith Zoltan, Gallo, Waldir Luiz R., Gasparetto, Carlos A.
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format79f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds