Return to search

Comparison of the effects of low dose and high dose inhaled corticosteroid treatment of mild to moderate asthma in adults.

Doctor of Philosophy (PhD) / Asthma is a chronic inflammatory disease of the airways. Corticosteroid medication is the most effective currently available treatment. Complications of corticosteroid therapy are dose-dependent, however, the clinical efficacy of varying doses of inhaled corticosteroids has been studied with mixed results. A randomized, double-blind, parallel group study was used to evaluate the inhaled corticosteroid dose-response relationship for clinical endpoints and in vitro parameters of underlying airway inflammation and remodelling. The mannitol provocation test with Forced Oscillation Technique (FOT) was used to derive potential dose-differentiating endpoints. In vitro inflammatory markers were measured in alveolar macrophages from bronchoalveolar lavage. Basement membrane thickness was measured from bronchial biopsies. Eleven nonasthmatic subjects were enrolled for comparison. This thesis addresses the null hypothesis that there is no significant difference in clinical and biological effects between low dose (200mcg/day, n=11) and high dose (1000mcg/day, n=11) treatment (for 6-7 weeks) with inhaled fluticasone propionate (FP) for a range of clinical outcomes and in vitro markers of airway inflammation and remodelling. Significant changes after FP included increased FEV1, reduced airway hyperresponsiveness (AHR) (by FOT and FEV1), exhaled nitric oxide and Juniper symptom score. In addition, significant reductions occurred in expression of GM-CSF, TNF-alpha and IL-1ra in macrophages. A lower baseline FOT-derived respiratory system conductance was predictive of a greater degree of improvement in symptoms. No statistically significant differences in the changes after treatment between low and high dose FP were found in spirometry, exhaled nitric oxide, symptom scores, AHR, alveolar macrophage cytokine levels (GM-CSF, TNF-alpha, IL-1ra, IL-10) and basement membrane thickness, although there were trends towards greater improvements in many of the parameters after high dose FP. Basement membrane thickness appeared to be reduced by high dose FP, although this reduction was not statistically significant. There was a weak, but statistically significant, negative correlation between basement membrane thickness and FOT-derived conductance (r2=0.135, p=0.042). With the recognition of the limitations in the interpretation of these data, the results suggest that, in previously steroid naïve mild to moderate asthmatics, there may be only minimal benefit derived from an additional 800µg/day of inhaled fluticasone above the low dose of 200µg/day.

Identiferoai:union.ndltd.org:ADTP/230155
Date January 2008
CreatorsBaraket, Melissa, mbaraket@med.usyd.edu.au
PublisherUniversity of Sydney., Discipline of Pharmacology, Faculty of Medicine
Source SetsAustraliasian Digital Theses Program
Detected LanguageEnglish
RightsThe author retains copyright of this thesis., http://www.library.usyd.edu.au/copyright.html

Page generated in 0.0025 seconds