Experimental and analytic investigations were performed to examine the influences of wall height, backfill behavior, and compaction on the magnitudes of backfill loads on rigid retaining walls.
Measurements of lateral and vertical backfill loads were made during tests using the Virginia Tech instrumented retaining wall facility. The tests were performed with two soils, moist Yatesville silty sand and dry Light Castle sand. Two hand-operated compactors, a vibrating plate compactor and a rammer compactor, were used to compact the backfill. The backfill height was 6.5 feet in all of the tests.
Analyses of backfill loads were made using a compaction- induced lateral earth pressure theory and a vertical shear force theory. The compaction-induced lateral earth pressure theory was revised from a previous theory. The revisions improved the accuracy with which the theory models the hysteretic stress behavior of the backfill during compaction. The theory was also extended to include the pore pressure response of moist backfill in a rational manner.
A vertical shear force theory was also developed during this research. The theory is based on consideration of backfill compressibility and mobilization of interface shear strength at the contact between the backfill and the wall. The theory provides a useful basis for understanding how wall height, backfill compressibility, wall-backfill interface behavior, and compaction-induced lateral pressures affect the vertical shear forces on rigid walls.
Studies were also made to investigate the cause of erratic pressure cell readings. An important cause of drift in pressure cell readings was found to be moisture changes in the concrete in which the pressure cells were mounted. It was found that this problem could be mitigated by applying a water-seal treatment to the face of the wall.
Both the vibrating plate compactor and the rammer compactor were instrumented to measure dynamic forces and energy transfer during compaction. The force applied by the vibrating plate compactor was about one-quarter of the manufacturer’s rated force. The force applied by the rammer compactor was about twice the manufacturer’s rated force. The transferred energy measurements provided a basis for relating laboratory and field compaction procedures. / Ph. D.
Identifer | oai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/37882 |
Date | 22 May 2007 |
Creators | Filz, George M. |
Contributors | Civil Engineering, Duncan, James M., Brandon, Thomas L., Clough, G. Wayne, Kuppusamy, Thangavelu, Reddy, Junuthula N. |
Publisher | Virginia Tech |
Source Sets | Virginia Tech Theses and Dissertation |
Language | English |
Detected Language | English |
Type | Dissertation, Text |
Format | xvii, 345 leaves, BTD, application/pdf, application/pdf |
Rights | In Copyright, http://rightsstatements.org/vocab/InC/1.0/ |
Relation | OCLC# 26166940, LD5655.V856_1992.F549.pdf |
Page generated in 0.0012 seconds