Previous issue date: 2016-04-18 / Este trabalho teve o propósito de determinar o comportamento dos gases na seção de
radiação de um combustor de ar que pertence a uma planta industrial. O corpo metálico
do equipamento rompeu em seu primeiro ano de operação, devido a um problema
conceitual em sua geometria. A fluidodinâmica computacional (CFD), por meio do
método dos volumes finitos, foi utilizada para desenvolver um modelo tridimensional
que pudesse reproduzir o perfil de temperatura e o comportamento do fluxo do ar de
combustão no equipamento. Na simulação, através do uso do software ANSYS CFX,
foram utilizados: (i) o modelo de turbulência Reynolds Stress Model (RSM); (ii) as
malhas hexaédrica, tetraédrica e prismática; (iii) o modelo de radiação P-1; e (iv) o
modelo de combustão Eddy Dissipation Concept (EDC). Como resultado, foram
apresentadas quatro possíveis mudanças na geometria do combustor de ar que, caso
adotadas, eliminariam os riscos de novas falhas e garantiriam a continuidade
operacional da unidade de processo. / This paper has the objective to describe the behavior of the flow and temperature of the
flue gas in the radiation section of the vessel used to preheat air in a combustor. The
equipment failed in its first operational year, due to a conceptual problem in its
geometry. The CFD code based on finite volume method was applied to simulate the
physical model of combustor using the ANSYS CFX software, reproducing the main
features of the preheater. The simulation had considered: (i) Reynolds Stress Model
(RSM) as turbulence model, (ii) The meshes applied were the hexahedral, tetrahedral
and prismatic, (iii) P-1 was used as the radiation model and (iv) Eddy Dissipation
Concept (EDC) as combustion model. Through the simulation was possible to propose
four different kind of combustor geometry modification, that the application of anyone of
them would eliminate the risk of new failures, ensuring the unit production availability.
Identifer | oai:union.ndltd.org:IBICT/oai:localhost:riufcg/309 |
Date | 23 March 2018 |
Creators | CURSINO, Gustavo Gomes Sampaio. |
Contributors | ALVES, José Jailson Nicácio., ARAÚJO, Antônio Carlos Brandão de., BRITO, André Luiz F., PEREIRA NETO, Antônio Tavernard., SILVA, Sidinei Kleber da., SILVERIO, Rodolfo Jesus Rodriguez. |
Publisher | Universidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA, UFCG, Brasil, Centro de Ciências e Tecnologia - CCT |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds