Return to search

Controle ativo de vibrações e localização ótima de sensores e atuadores piezelétricos

Made available in DSpace on 2014-06-11T19:27:14Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-09-24Bitstream added on 2014-06-13T20:55:55Z : No. of bitstreams: 1
bueno_dd_me_ilha.pdf: 2346457 bytes, checksum: 53a7ababeeced81edd91bb8ef04b1c0f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho apresenta o projeto do regulador linear quadrático (LQR – do inglês Linear Quadratic Regulator) para atenuar vibrações em estruturas mecânicas. Estas estruturas, com atuadores e sensores acoplados, são denominadas estruturas inteligentes. Os projetos de controladores ativos são resolvidos utilizando desigualdades matriciais lineares (LMIs – do inglês Linear Matrix Inequalities). Assim, é possível projetar controladores robustos considerando incertezas paramétricas na planta a ser controlada. São utilizados atuadores e sensores piezelétricos (PZTs) para aplicações em estruturas flexíveis dos tipos vigas e placas e, também, atuadores de pilha para aplicações em estruturas do tipo treliça. O problema do posicionamento ótimo dos atuadores e sensores piezelétricos também é resolvido utilizando as normas de sistemas H2, H , Hankel e as matrizes grammianas de observabilidade e controlabilidade. O modelo matemático da estrutura inteligente é obtido a partir do Método dos Elementos Finitos e, também, utilizando o Método de Identificação de Subespaços através de dados experimentais. O problema de posicionamento ótimo dos atuadores e sensores e o controle ativo de vibração são apresentados em simulações numéricas e experimentais. Os resultados mostram que os controladores robustos aumentam o amortecimento estrutural minimizando as amplitudes de vibração. / This work presents the Linear Quadratic Regulator design to vibration attenuation in mechanical structures. These structures are named Smart Structures because they use actuators and sensors electromechanically coupled. Active controller designs are solved using Linear Matrix Inequalities. So, it is possible to consider polytopic uncertainties. Piezoelectric actuators and sensors are used for applications in flexible structures as beams and plates and, also, stack actuators for applications in truss structures. Optimal placement problem of piezoelectric actuators and sensors also solved using H2, H , Hankel system norms and controllability and observability grammian matrices. The mathematical model of the smart structure is obtained through Finite Element Method and, also, through Numerical State Space of Subspace System Identification (Subspace Method) by experimental data. The optimal placement of actuator and sensor and the active vibration control is numerically and experimentally implemented. Results show that the robust controllers increase the structural damping minimizing magnitude of vibrations.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/94556
Date24 September 2007
CreatorsBueno, Douglas Domingues [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Júnior, Vicente Lopes [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format230 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0026 seconds