Return to search

Aplicativo web para projeto de sensores ópticos baseados em ressonância de plasmons de superífice em interfaces planares

Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2017-01-30T18:17:26Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTACAO_LEO_DEFESA - FINAL - CATALOGADA PDF.pdf: 4585329 bytes, checksum: 4b70c80127866cd2da97a6217bb6a34f (MD5) / Made available in DSpace on 2017-01-30T18:17:27Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTACAO_LEO_DEFESA - FINAL - CATALOGADA PDF.pdf: 4585329 bytes, checksum: 4b70c80127866cd2da97a6217bb6a34f (MD5)
Previous issue date: 2016-08-16 / CNPQ / Um dos principais desafios no projeto de sensores baseados em Ressonância de Plasmons de Superfície — RPS — é maximizar sua sensibilidade. Neste trabalho é proposto o uso de dois algoritmos heurísticos, Monte Carlo e Enxame de Partículas, para otimização de sensores baseados em RPS em interfaces planares, i.e, nas configurações de Kretschmann e de Otto, sem o auxílio da aproximação lorentziana para a curva de ressonância. Devido à natureza probabilística dos algoritmos, consegue-se obter um método simples e robusto para atingir essa otimização. É feita uma comparação quanto à eficiência computacional dos algoritmos em relação ao método tradicional de otimização, ficando demonstrado que o método de Enxame de Partículas é o mais eficiente em relação às outras técnicas. Com o emprego desse método, a dependência espectral dos parâmetros ótimos é obtida para sensores utilizando vários metais nas configurações de Kretschmann e de Otto, tanto para aplicações em meios gasosos quanto em meios aquosos. Um aplicativo foi desenvolvido e sua funcionalidade demonstrada, que pode ser executado diretamente via web, com base na metodologia proposta, para otimização de sensores RPS em interfaces planares. / One of the main challenges in the design of surface plasmon resonance – SPR – sensor systems is to maximize their sensitivity. In this work one proposes the use of two heuristic algorithms, Monte Carlo and Particle Swarm, for optimization of SPR sensors in planar interfaces, i.e, in the Kretschmann and Otto configurations, without use of the Lorentzian approximation to the resonance curve. Because of the probabilistic nature of the algorithms, one manages to obtain a simple and robust method to achieve optimization. A comparison is made on the computational efficiency of the algorithm relative to the traditional method of optimization, showing that the particle swarm optimization method is more efficient compared to other techniques. By employing this method, the spectral dependence of optimum parameters is obtained for sensors using a wide range of metal films in the Kretschmann and Otto configurations, both for applications in gaseous an in aqueous media. An app was developed and its functionality can be demonstrated, by direct execution via web, based on the proposed methodology for optimization of SPR sensors on planar interfaces.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/18272
Date16 August 2016
CreatorsCAVALCANTI, Leonardo Machado
Contributorshttp://lattes.cnpq.br/5989233042856714, FONTANA, Eduardo
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Eletrica, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds