Return to search

Avaliação comparativa por meio de testes mecânicos, análise extensométrica e fotoelástica da influência da realização ou não da osteotomia da base nas osteotomias sagitais dos ramos mandibulares / Comparative evaluation by mechanical testing, analysis extensometric and photoelastic at the influence of basilar osteotomy in sagittal osteotomies

Orientador: José Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba. / Made available in DSpace on 2018-08-20T01:39:48Z (GMT). No. of bitstreams: 1
Cabral-Andrade_Valdir_M.pdf: 2554505 bytes, checksum: 59b3398b4be124c9a3c5db0bc28f73f2 (MD5)
Previous issue date: 2012 / Resumo: O objetivo deste estudo foi avaliar a influência da osteotomia da base mandibular nas osteotomias sagitais do ramo, comparando como ela modifica a resistência mecânica dos sistemas de fixação, bem como a distribuição de tensões, utilizando como metodologia os testes mecânicos, extensiométricos e de fotoelasticidade. Para os testes mecânico e extensométrico, foi utilizada uma amostra composta de 20 hemimandíbulas confeccionadas em poliuretano, sendo 10 hemimandíbulas para cada tipo de osteotomia fixadas com parafusos bicorticais posicionais em L invertido, as quais foram submetidas à incidência de carga analisada por extensometria até a falha do sistema de fixação através de teste de carregamento linear a uma velocidade de 1mm/min. Para o teste mecânico, não existiu diferença em termos de carga e deslocamento final. Para a análise extensométrica, não existiu diferença estatisticamente significante entre os parafusos 1 e 3 entre as amostras, somente para o parafuso 2. No caso da análise fotoelástica, a osteotomia da base mostrou apresentar melhor padrão de distribuição de tensões. Apesar dessas diferenças estatísticas, clinicamente elas não devem influenciar em termos de resistência mecânica, podendo ambas ser utilizadas dependendo do caso e da preferência de cada profissional / Abstract: The aim of this study was to evaluate the osteotomy of the inferior border of the mandible, comparing the mechanical resistance of the fixation system, as the tension distribuition, using the mechanical, extensiometric and photoelastic methodology. For the mechanical and extensiometic analysis, a sample of 20 polyurethane hemimandibles were made, 10 hemimandible for each type of osteotomy, fixed with positional bicortical screws in inverted L configuration, that were submitted to linear loading with a displacement of 1 mm/min until the fixation failure, with extensiometric analysis. The mechanical tests found no difference for final loading and displacement. For the extensiometric analysis, there was no statistical difference between the screws 1 and 3, just for the screw 2. In the photoelastic analysis, the osteotomy of the inferior border of the mandible presented better stress distribution pattern. Despite those differences in the in vitro tests, the inferior border osteotomy probably does not have clinical influence in the resistance and it should be done depending on the case and the preference of the professional / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289445
Date03 September 2012
CreatorsCabral-Andrade, Valdir, 1985-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Albergaria-Barbosa, José Ricardo de, 1956-, Luz, João Gualberto de Cerqueira, Silvério, Karina Gonzales
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format69 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds