Return to search

On-Site Excreta Treatment and Disposal in West Africa

In operation, liquid from the test facility is circulated through the RHS core. The liquid is heated by passing over the resistance heaters. If the test facility's calibrations are under investigation, the RHS input power and temperatures are compared with those recorded by the test facility. If a collector is under test, the RHS is placed in series with the collector. The power input to the RHS is placed in series with the collector. The power input to the RHS core heaters is adjusted to give a temperature rise through the RHS equal to some fraction (usually one-half to one) of the temperature rise across the collector. Since the same mass flow passes through both the RHS and the collector, the energy gain in the collector is simply the RHS input power multiplied by the ratio of the temperature rises.

Identiferoai:union.ndltd.org:ucf.edu/oai:stars.library.ucf.edu:rtd-1636
Date01 July 1982
CreatorsIgbokwe, Godfrey E.
PublisherSTARS
Source SetsUniversity of Central Florida
LanguageEnglish
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceRetrospective Theses and Dissertations
RightsPublic Domain

Page generated in 0.0019 seconds