Flow distribution has big importance in equipment with limited tube rows because it provides correct operation and sometimes specific flow distribution for technology purposes is needed. This thesis is focusing on flow analysis in these units using computational fluid dynamics (CFD). For analysis of such systems models with varying tube rows and varying perforated segment lengths were created. Analysis showed significant impact of flow manifold layout along with tube layout and number of tubes. Simplified 1D model using static pressure regain coefficient was created which provides much shorter computational times. Comparison of 1D and CFD models was made to determine field of their usage.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:377756 |
Date | January 2018 |
Creators | Chýlek, Martin |
Contributors | Babička Fialová, Dominika, Turek, Vojtěch |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |