This master thesis was tasked to find out how the parameter of interior atmosphere changes at student's club "Mrtvá Ryba", that means atmospheric aerosols sized from 0,524 to 20 micrometers. This work tries to show indoor aerosols before and after the smoking ban and its comparison. This work describes concentrations PM1 and PM10, and their behavior per day. Concentrations was measured by APS (Aerodynamic particle sizer). The measurement was the first step in the non-smoking club, then processing with retrieved informations in CoPlot, CoStat and Excel, where the statistical method has done, and comparison with previous values. T-tests was used for statistics and linear regresion. The result confirms, what was it supposed to, so concentracion values are significantly different. The average concentration of all measured days (six) of smoking campaign was at PM1 13,28 µg.m-3 and at PM10 23,38 µg.m-3. The average concentration of all measured days (thirty six) of non-smoking campaign was at PM1 4,88 µg.m-3 and at PM10 24,61 µg.m-3. Resulting concentration of aerosol particles was explicity lower at non-smoking period than at smoking period. Contamination of interior enviroment is influenced by many factors. The most important factor is presence of persons and their number, concentration of outdoor...
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:286377 |
Date | January 2010 |
Creators | Valchářová, Tereza |
Contributors | Ondráček, Jakub, Hovorka, Jan |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0017 seconds